App - 24 App - 24
APPENDIXES
Availability
(
: Available,
: Not available)
Online
Number Name
Description
Master station
Local station
Offline
SB004A
(5E4
H
, b10)
Temporary error
invalid canceling
acknowledgement
status
Indicates the acknowledgement status of remote station temporary
error invalid cancel instruction.
OFF: Not executed
ON : Instruction acknowledged
SB004B
(5E4
H
, b11)
Temporary error
invalid canceling
complete status
Indicates the acknowledgement completion status of remote station
temporary error invalid cancel instruction.
OFF: Not executed
ON : Temporary error invalid station cancellation complete
SB004C
(5E4
H
, b12)
Loop test acceptance
status
Indicates the loop test request acknowledgement status.
OFF: Not executed
ON : Instruction acknowledged
SB004D
(5E4
H
, b13)
Loop test complete
status
Indicates the loop test completion status.
OFF: Not executed
ON : Test complete
SB004E
(5E4
H
, b14)
Parameter information
read
acknowledgement
status
Indicates the parameter information read request acknowledgement
status.
OFF: Not executed
ON : Instruction acknowledged
SB004F
(5E4
H
, b15)
Parameter information
read completion
status
Indicates the completion status of the parameter information read
request.
OFF: Not executed
ON : Test complete
SB0050
(5E5
H
, b0)
Offline test status
Indicates the offline test execution status.
OFF: Not executed
ON : In progress
SB0057
(5E5
H
, b7)
Master station
duplication error
canceling
acknowledgement
Indicates the acknowledgement status of master station duplication
error canceling request.
OFF: Not acknowledged
ON : Acknowledged
SB0058
(5E5
H
, b8)
Master station
duplication error
canceling complete
Indicates the completion status of master station duplication error
canceling request.
OFF: Not complete
ON : Complete
SB005A
(5E5
H
, b10)
Master switching
request
acknowledgement
Indicates the acknowledgement status of the standby master station
when it has received a master switching request from the line.
OFF: Not acknowledged
ON : Request acknowledged
SB005B
(5E5
H
, b11)
Master switching
request complete
Indicates whether or not the switching from the standby master
station to master station is complete.
OFF: Not complete
ON : Complete
SB005C
(5E5
H
, b12)
Forced master
switching request
acknowledgement
Indicates whether or not a forced master switching request has been
acknowledged.
OFF: Not acknowledged
ON : Instruction acknowledged
1
SB005D
(5E5
H
, b13)
Forced master
switching request
complete
Indicates whether or not a forced master switching request is
complete.
OFF: Not complete
ON : Complete
1
SB005E
(5E5
H
, b14)
Execution status of
remote device station
initialization procedure
Indicates the execution status of the initialization procedure.
OFF: Not executed
ON : Being executed
3
SB005F
(5E5
H
, b15)
Completion status of
remote device station
initialization procedure
Indicates the completion status of the initialization procedure
execution.
OFF: Not complete
ON : Complete
3
1: Can be used for the standby master station only.
3: Parameter setting is required in the case of a standby master station.
(To the next page)
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......