App - 12 App - 12
APPENDIXES
(4) Slave station offset, size information
In the remote net ver.2 mode or remote net additional mode, the assignment of
RX/RY/RWw/RWr for the station numbers varies according to the expanded
cyclic setting and remote I/O station points setting.
(a) Offset
Stores the head buffer memory address of RX/RY/RWw/RWr assigned to
each station.
When 2 or more stations are occupied, values are stored into only the head
buffer memory address of the station number. (When station No. 1
occupies 2 stations, values are stored into the RX/RY/RWw/RWr offset and
size of station No. 1, and the RX/RY/RWw/RWr offset and size of station
No. 2 remains default.)
(b) Size
Stores the size of RX/RY/RWw/RWr assigned to each station in word unit.
When the size is less than 1 word, it is rounded up and 1 is stored. (When
the remote I/O station points setting is 8 points, 1 is stored.)
Refer to Section 8.3.9 for the remote I/O station points setting method.
For the reserved station, 0000
H
is stored.
The following table lists the correspondence between station numbers and the
buffer memory address of RX/RY/RWw/RWr offset and size.
Buffer memory address
Hex. Dec.
Item Default
(Hex.)
3E0
H
992
Station No. 1 RX offset
0000
H
3E1
H
993
Station No. 1 RX size
0000
H
to to
to
—
45E
H
1118
Station No. 64 RX offset
0000
H
45F
H
1119
Station No. 64 RX size
0000
H
460
H
1120
Station No. 1 RY offset
0000
H
461
H
1121
Station No. 1 RY size
0000
H
to to
to
—
4DE
H
1246
Station No. 64 RY offset
0000
H
4DF
H
1247
Station No. 64 RY size
0000
H
4E0
H
1248
Station No. 1 RWw offset
0000
H
4E1
H
1249
Station No. 1 RWw size
0000
H
to to
to
—
55E
H
1374
Station No. 64 RWw offset
0000
H
55F
H
1375
Station No. 64 RWw size
0000
H
560
H
1376
Station No. 1 RWr offset
0000
H
561
H
1377
Station No. 1 RWr size
0000
H
to to
to
—
5DE
H
1502
Station No. 64 RWr offset
0000
H
5DF
H
1503
Station No. 64 RWr size
0000
H
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......