App - 20 App - 20
APPENDIXES
(b) Master station (RWr)
←
remote device station (RWr)/local station (RWw)
1) Master station
The send data from the remote register (RWr) of the remote device
station and the remote register (RWw) of the local station is stored.
When 1 station is occupied, any of 4 to 32 words are used. The
number of used points changes depending on the expanded cyclic
setting and the number of occupied stations. (Refer to Section 3.2)
2) Local station
Data is sent to the master station and other local stations by storing it
in the address corresponding to the host station number.
Data in the remote register (RWr) of the remote device station can also
be received.
When 1 station is occupied, any of 4 to 32 words are used. The
number of used points changes depending on the expanded cyclic
setting and the number of occupied stations. (Refer to Section 3.2)
Remote register (RWr)
4C00
H
4C01
H
4C02
H
4C03
H
4C04
H
4C05
H
4C06
H
4C07
H
4C08
H
4C09
H
4C0A
H
4C0B
H
4C0C
H
4C0D
H
4C0E
H
4C0F
H
4C10
H
4C11
H
4C12
H
4C13
H
53FC
H
53FD
H
53FE
H
53FF
H
RWr 0
RWr 1
RWr 2
RWr 3
Remote register (RWr)
Remote register (RWw)
RWr 0
RWr 1
RWr 2
RWr 3
RWr 4
RWr 5
RWr 6
RWr 7
RWr 8
RWr 9
RWr A
RWr B
RWr C
RWr D
RWr E
RWr F
RWr 10
RWr 11
RWr 12
RWr 13
RWr 7FC
RWr 7FD
RWr 7FE
RWr 7FF
4400
H
4401
H
4402
H
4403
H
4404
H
4405
H
4406
H
4407
H
4408
H
4409
H
440A
H
440B
H
440C
H
440D
H
440E
H
440F
H
4410
H
4411
H
4412
H
4413
H
4BFC
H
4BFD
H
4BFE
H
4BFF
H
Master station
Remote device station
(Station number 1: Occupies 1 station,
Expanded cyclic setting: single)
Local station
(Station number 2: Occupies 1 station,
Expanded cyclic setting: quadruple)
Address
Address
RWw 0
RWw 1
RWw 2
RWw 3
RWw 4
RWw 5
RWw 6
RWw 7
RWw 8
RWw 9
RWw A
RWw B
RWw C
RWw D
RWw E
RWw F
RWw 10
RWw 11
RWw 12
RWw 13
RWw 7FC
RWw 7FD
RWw 7FE
RWw 7FF
to
to
to
to
(Example)
Station
number 1
Station
number 2
Station
number 1
Station
number 2
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......