(4) Enable initial settings
Before creating a program for communication with remote device stations, create
a program to enable the initial settings using SB000D (remote device station
initialization procedure registration instruction) and SB005F (completion status of
remote device station initialization procedure execution).
For details, refer to Sections 11.1.3, 11.2.3 and 11.3.3.
Procedure for the remote device station initialization procedure registration
(a) Turn SB000D ON, and start to execute the registered initial setting.
During execution of initial processing, SB005E (remote device station
initialization procedure execution status) stays ON.
Also, the execution procedure numbers and target station numbers of the
registration are stored to SW0110 to SW011F (remote device station
initialization procedure registration execution individual information).
(b) When initial processing of all preset stations is completed, SB005F turns ON.
Also, the execution result is stored to SW005F (remote device station
initialization procedure instruction result).
The execution procedure numbers in SW0110 to SW011F become FF00H.
(c) When SB000D is turned OFF on completion of initial processing (SB005F :
ON), SB005F, and SW0110 to SW011F are cleared.
The following shows operation of the link special relays and link special registers
when remote device station initialization procedure registration is performed.
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......