3 - 21 3 - 21
3 SPECIFICATIONS
Address
Availability
Hexadecimal Decimal
Item Description
Read/write
possibility
Master
station
Local
station
Reference
For the master station: Stores the receive data
from the remote
device/local/intelligent
device/standby master
stations.
—
2E0
H
to
3DF
H
736
to
991
Remote register
(RWr)
2
Master station:
For receiving
Local station:
For receiving
For the local station : Stores the receive data
from the master station.
Read only
—
Appendix
2 (3)
3E0
H
to
5DF
H
992
to
1503
Slave station offset,
size information
Stores the offset and size of RX/RY/RWw/RWr
per slave station.
Read only
Appendix
2 (4)
5E0
H
to
5FF
H
1504
to
1535
Link special relay (SB) Stores the data link status.
Appendix
2 (5)
600
H
to
7FF
H
1536
to
2047
Link special register
(SW)
Stores the data link status.
Read/write
enabled
(write may
be disabled
depending
on the
device)
Appendix
2 (6)
800
H
to
9FF
H
2048
to
2559
Use prohibited
1
— —
—
—
—
A00
H
to
FFF
H
2560
to
4095
Random access buffer
The specified data is stored and used by
transient transmission.
Read/write
enabled
Appendix
2 (7)
1000
H
to
1FFF
H
4096
to
8191
Communication buffers
Stores the send and receive data and control
data when performing transient transmission
(communication using this buffer) with the local
station, standby master station, and intelligent
device station.
Read/write
enabled
Appendix
2 (8)
2000
H
to
2FFF
H
8192
to
12287
Automatic update
buffer
Stores the automatically updated data when
performing transient transmission with the
AJ65BT-R2N (communication using the
automatic update buffer).
Read/write
enabled
—
Appendix
2 (9)
3000
H
to
3FFF
H
12288
to
16383
Use prohibited
1
— —
—
—
—
: Available, — : Not available
(To the next page)
1 Do not write any data to the use-prohibited area. Doing so may cause an error.
2 Used when the remote net ver.1 mode or remote net additional mode is selected.
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......