App - 18 App - 18
APPENDIXES
(b) Master station Remote I/O station/remote device station/local station
1) Master station
The output status to the remote I/O station, remote device station (RY)
and all local stations (RX) is stored.
When 1 station is occupied, 2, 4 or 8 words are used. The number of
used points changes depending on the extended cyclic setting and the
number of occupied stations. (Refer to Section 3.2)
2) Local station
The data received from remote I/O stations, remote device stations
(RY) and master station (RY) are stored.
When 1 station is occupied, any of 2 to 8 words are used. The number
of used points changes depending on the extended cyclic setting and
the number of occupied stations. (Refer to Section 3.2)
… The last two bits cannot be used for communication between the master
station and the local station.
(In the example below, RYEE and RYEF cannot be used.)
Address
Master station
Remote I/O station
(Station number 1: Occupies 1
station, Remote I/O station
point setting: 16-point setting)
Address
Remote input (RX)
Local station
(Station number 3: Occupies 4
stations, Expanded cyclic
setting, double)
Station
number 1
Station
number 2
(Example)
Station
number 3
Station
number 7
Remote I/O station
(Station number 2: Occupies 1
station, Remote I/O station
point setting: 32-point setting)
Y1F to Y10
Y2F to Y20
Address
Remote input (RX)
Local station
(Station number 7: Occupies 4
stations, Expanded cyclic setting,
double)
4200
H
4201
H
4202
H
4203
H
4204
H
420F
H
4210
H
4211
H
43FC
H
Y0F to Y00
43FD
H
43FE
H
43FF
H
4212
H
421D
H
421E
H
4000
H
RX F to RX 0
4001
H
4002
H
4003
H
4004
H
400F
H
4010
H
4011
H
41FC
H
RX 1F to RX 10
RX 2F to RX 20
RX 11F to RX 110
RX1FCF to RX1FC0
RX1FDF to RX1FD0
RX1FEF to RX1FE0
RX1FFF to RX1FF0
41FD
H
41FE
H
41FF
H
4012
H
401D
H
401E
H
RX 12F to RX 120
RX 1DF to RX 1D0
RX 1EF to RX 1E0
4000
H
RX F to RX 0
4001
H
4002
H
4003
H
4004
H
400F
H
4010
H
4011
H
41FC
H
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX FF to RX F0
RX 10F to RX 100
RX1FCF to RX1FC0
RX1FDF to RX1FD0
RX1FEF to RX1FE0
RX1FFF to RX1FF0
41FD
H
41FE
H
41FF
H
4012
H
401D
H
401E
H
Station
number 1
Station
number 2
Station
number 3
Station
number 7
Station
number 1
Station
number 2
Station
number 3
Station
number 7
RX FF to RX F0
RX 4F to RX 40
RX 3F to RX 30
RX 10F to RX 100
RX 11F to RX 110
RX 12F to RX 120
RX 1DF to RX 1D0
RX 1EF to RX 1E0
Remote output (RY)
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY FF to RY F0
RY 10D to RY 100
RY 11F to RY 110
RY1FCF to RY1FC0
RY1FDF to RY1FD0
RY1FEF to RY1FE0
RY1FFF to RY1FF0
RY 12F to RY 120
RY 1EF to RY 1E0
RY 1DF to RY 1D0
POINT
The assignment range of each station in the preset station information can be
confirmed by the slave station offset and size information (buffer memory
addresses 3E0
H
to 5DF
H
). (Refer to Appendix 2 (4).)
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......