3 - 8 3 - 8
3 SPECIFICATIONS
3.3 Function List
The following shows the function list of the L series master/local module.
(1) List of the "basic functions"
Item Description
Reference
Communication with remote I/O
stations
Performs on/off data communication with remote I/O stations.
Section 8.1.1
Communication with remote device
stations
Performs on/off data and numeric data communication with
remote device stations.
Section 8.1.2
Communication with local stations
Performs on/off data and numeric data communication with local
stations.
Section 8.1.3
Communication with intelligent
device stations
Performs communication with intelligent device station, by cyclic
transmission, and transient transmissions.
Section 8.1.4
(2) List of the "functions for improving system reliability"
Item Description
Reference
Slave station cut-off function
Disconnects a slave station that cannot continue the data link
due to a reason such as power off, so that data link can continue
among normal slave stations only.
Section 8.2.1
Automatic return function
When a slave station, which has been disconnected from the
network due to a reason such as power off, returns to the normal
status, it automatically joins the data link.
Section 8.2.2
Data link status setting when the
master station programmable
controller CPU has an error
Sets whether to stop or continue the data link when an error that
stops the operation occurs at the master station programmable
controller CPU in the system that has no standby master station.
When "Continue" is set, the diagnostics of the master station can
be performed from local stations.
Section 8.2.3
Setting the status of input data from
a data link faulty station
Sets whether to clear or hold the input data (remote input RX)
from a station that detected a data link error due to a reason
such as power off.
Section 8.2.4
Slave station refresh/compulsory
clear setting in case of
programmable controller CPU
STOP
Sets whether to refresh or forcibly clear output data (remote
output RY) to the slave stations when the programmable
controller CPU comes to STOP.
When "Clears Compulsorily" is set, the remote output RY turns
off when the operation stops due to STOP of programmable
controller CPU or due to an error occurrence.
Section 8.2.5
Standby master function
Continues the data link by switching the control to the standby
master station when a problem occurs in the master station.
Section 8.2.7
Data link start by standby master
station
Starts data link when either of the master or standby master
station is turned on.
Section 8.2.8
Block guarantee of cyclic data per
station
Guarantees the consistency of the cyclic data for each slave
station.
Section 8.2.9
Guarantee of 32-bit data
Guarantees the 32-bit data of the remote register (RWr/RWw)
between programmable controller CPU and the master/local
station.
Section 8.2.10
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......