App - 17 App - 17
APPENDIXES
(10) Ver.2 compatible remote input (RX) and Ver.2 compatible remote
output (RY)
Used when the remote net ver.2 mode or remote net additional mode is selected.
(a) Master station Remote I/O station/remote device station/local station
1) Master station
The input status from the remote I/O station, remote device station
(RX) and local station (RY) is stored.
When 1 station is occupied, 2, 4 or 8 words are used. The number of
used points changes depending on the extended cyclic setting and the
number of occupied stations. (Refer to Section 3.2)
2) Local station
Data to be sent to the master station is stored in the remote output
(RY) of the address corresponding to the host station number.
The input status from the remote I/O station, remote device station
(RX) and other local station is stored.
When 1 station is occupied, any of 2 to 8 words are used. The number
of used points changes depending on the extended cyclic setting and
the number of occupied stations. (Refer to Section 3.2)
… The last two bits cannot be used for communication between the master
station and the local station.
(In the example below, RYEE and RYEF cannot be used.)
4000
H
RX F to RX 0
4001
H
4002
H
4003
H
4004
H
400F
H
4010
H
4011
H
41FC
H
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX FF to RX F0
RX 10D to RX 100
RX 11F to RX 110
RX1FCF to RX1FC0
RX1FDF to RX1FD0
RX1FEF to RX1FE0
RX1FFF to RX1FF0
Address
Remote input (RX)
X0F to X00
Master station
Remote I/O station
(Station number 1: Occupies 1
station, Remote I/O station
point setting:
16-point setting)
Address
Remote output (RY)
Local station
(Station number 3: Occupies 4
stations, Expanded cyclic
setting, double)
41FD
H
41FE
H
41FF
H
4012
H
400D
H
400E
H
RX 12F to RX 120
RX 1DF to RX 1D0
RX 1EF to RX 1E0
4200
H
RY F to RY 0
4201
H
4202
H
4203
H
4204
H
420F
H
4210
H
4211
H
43FC
H
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY FF to RY F0
RY 10D to RY 100
RY 11F to RY 110
RY1FCF to RY1FC0
RY1FDF to RY1FD0
RY1FEF to RY1FE0
RY1FFF to RY1FF0
43FD
H
43FE
H
43FF
H
Station
number 1
Station
number 2
4212
H
421D
H
421E
H
RY 12F to RY 120
RY 1DF to RY 1D0
RY 1EF to RY 1E0
(Example)
Station
number 2
Station
number 7
Remote I/O station
(Station number 2: Occupies 1
station, Remote I/O station
point setting:
32-point setting)
X1F to X10
X2F to X20
Station
number 3
Station
number 7
Address
Remote output (RY)
Local station
(Station number 7: Occupies 4
stations, Expanded cyclic
setting, double)
4200
H
RY F to RY 0
4201
H
4202
H
4203
H
4204
H
420F
H
4210
H
4211
H
43FC
H
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY FF to RY F0
RY 10D to RY 100
RY 11F to RY 110
RY1FCF to RY1FC0
RY1FDF to RY1FD0
RY1FEF to RY1FE0
RY1FFF to RY1FF0
43FD
H
43FE
H
43FF
H
4212
H
421D
H
421E
H
RY 12F to RY 120
RY 1DF to RY 1D0
RY 1EF to RY 1E0
Station
number 1
Station
number 3
Station
number 1
Station
number 2
Station
number 3
Station
number 7
POINT
The assignment range of each station in the preset station information can be
confirmed by the slave station offset and size information (buffer memory
addresses 3E0
H
to 5DF
H
). (Refer to Appendix 2 (4).)
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......