3 - 16 3 - 16
3 SPECIFICATIONS
2 A link is performed as shown in the following areas.
Ver. 1
compatible
remote
output RY
Station number 1
Master station
additional mode
Local station
Ver. 1 mode
(Station number 1:
Occupies 1 station)
Local station
Ver. 2 mode
(Station number 2:
Occupies 1 station)
Local station
additional mode
(Station number 3:
Occupies 4 stations)
Standby master station
additional mode
(Station number 7:
Occupies 1 station)
to
Station number 4
Station number 3
Station number 5
Station number 6
Station number 7
Station number 2
to
Station number 4
Station number 3
Station number 5
Station number 6
Station number 7
Station number 2
to
Station number 4
Station number 3
Station number 5
Station number 6
Station number 7
Station number 2
to
Station number 4
Station number 3
Station number 5
Station number 6
Station number 7
Station number 2
to
Station number 1
to
Station number 1
to
Ver. 2
compatible
remote
output RY
Station number 1
Station number 2
Station number 3
Station number 4
Station number 5
Station number 6
Station number 7
to
double
octuple
double
Remote input RX
Station number 1
3 The remote net ver.2 mode and remote net additional mode cannot be used with
the QJ61BT11.
4 Data link is not available when the version set in the station type of the master
station information is different from that of the remote station.
For example, when the station type of the master station information is set as
"Ver.1 remote device station" although the actual remote device station is set to
"Ver.2 remote device station", data link cannot be performed with the "ERR." LED
on the master station flashing and the "L RUN" LED on the remote device station
turned OFF.
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......