3 - 14 3 - 14
3 SPECIFICATIONS
(2)
Remote net additional mode
This mode is designed for use when slave stations including a ver.2 compatible
station is added to the existing ver.1 system.
The program of the existing system can be used as is.
Master station
additional mode
Remote I/O station
(Station number 1:
Occupies 1 station)
Output
Remote output RY
Remote input RX
Station number 1
Station number 2
Station number 3
Station number 4
Station number 5
Station number 6
Station number 7
to
Remote output RY
Remote device station
Ver. 1 compatible
(Station number 2:
Occupies 2 stations)
Local station
additional mode
(Station number 4:
Occupies 4 stations)
Ver. 1
compatible
remote
output RY
Remote device station
Ver. 2 compatible
(Station number 8:
Occupies 1 station)
Station number 8
Ver. 2
compatible
remote
output RY
to
Station number 1
Station number 2
Station number 3
Station number 4
Station number 5
Station number 6
Station number 7
to
Station number 8
to
double
octuple
POINT
(1) Set the station numbers of the slave stations to be added after the last station
number used in the existing system.
In the above example, the slave stations are added to and after station No. 4
since the existing system uses up to station No. 3.
(2) When the ver.2 compatible slave station is added or deleted, the refresh devices
of the programmable controller CPU will vary by the number of points set to the
added or deleted slave station in the slave stations of the station numbers after
the added or deleted slave station. Confirm the varying number of points in
Section 3.2 (1).
(3) In the remote net additional mode, the ver.2 compatible slave station must be
placed in the latter half as described in (1).
When there is a possibility that ver.1 compatible slave stations will be added in
the future in the remote net additional mode, set multiple reserved stations after
the ver.1 compatible slave station to ensure ease of expanding the system.
(4) For the system that includes a standby master station, it is recommended to
change for the remote net ver.2 mode.
When the remote net additional mode is used, the program for the standby
master station must be corrected.
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......