APPENDIXES
Availability
(
: Available,
: Not available)
Online
Number Name
Description
Master station
Local station
Offline
SW0098
(698
H
)
SW0099
(699
H
)
SW009A
(69A
H
)
SW009B
(69B
H
)
Station number
overlap status
6
Stores the overlap status when the first station number of each
module is not overlapped.
0: Normal
1: Overlap station number (first station number only)
16
15
14
13
4
3
2
1
48
47
46
45
36
35
34
33
32
31
30
29
20
19
18
17
64
63
62
61
52
51
50
49
b15
b14
b13
b12
to
b3
b2
b1
b0
SW0098
SW0099
SW009A
SW009B
Numbers 1 to 64 in the above table indicate the station numbers.
to
to
to
to
Reserved stations and any station of the number higher than the
max. are excluded.
Unable to detect station number overlapping of standby master
stations.
For the slave stations with "Auto Following" set for transmission
speed, station numbers may not be detected even when any of
them are overlapping.
SW009C
(69C
H
)
SW009D
(69D
H
)
SW009E
(69E
H
)
SW009F
(69F
H
)
Loading/parameter
consistency status
6
Stores the consistency status between the loaded station and the
parameter settings.
A matching error occurs in any of the following cases.
1) Station type mismatch
2) Number of occupied stations mismatch
3) Expanded cyclic setting mismatch
4) CC-Link compatible version mismatch
A matching error will not occur when installation parameter. (For
example, a matching error will not occur when a remote device
station is installed and the parameter setting is an intelligent
device station.)
0: Normal
1: Matching error
Example of matching error
Installation
Remote device station
Intelligent device station
Parameter
Remote I/O station
Remote I/O station
Remote device station
16
15
14
13
4
3
2
1
48
47
46
45
36
35
34
33
32
31
30
29
20
19
18
17
64
63
62
61
52
51
50
49
b15
b14
b13
b12
to
b3
b2
b1
b0
SW009C
SW009D
SW009E
SW009F
Numbers 1 to 64 in the above table indicate the station numbers.
to
to
to
to
Reserved stations and any station of the number higher than the
max. are excluded.
6: Only the bit for the first station number is turned on.
The status is checked and stored only at link startup and at parameter update.
(To the next page)
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......