App - 68 App - 68
APPENDIXES
Appendix 7 When Using the GX Developer
Appendix 7.1 Compatible software package
Refer to the following manual.
MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and
Inspection)
Appendix 7.2 Operation comparison
The following shows the operating method to use the GX Developer.
For details on the operation of GX Developer, refer to the Operating Manual of GX
Developer.
(1) How to operate the wiring check
[Example of wiring check]
Specify the "Remote input (RX)" for the master station to "X1000" and the "Remote
output (RY)" to "Y1000" with the GX Developer.
Master station
Input module
Remote I/O station
(Station number 1, number
of occupied stations 1)
Output module
Remote I/O station
(Station number 2, number
of occupied stations 1)
X00
ON
ON
Y00
(a) Checking the wiring between the input module and an external device
1) Turn ON the switch corresponding to the external device "X0," which is
connected to the input module of station number 1.
2) Using the GX Developer, set "X1000" in the "Device:" field by choosing
[Online] [Monitor] [Device batch] and then click on "Start monitor".
3) If X1000 is ON, the connection between the input module and external
device has been properly performed.
(b) Checking the wiring between the output module and an external device
1) Using the GX Developer, set "Y1020" in the "Device:" field for the "Bit
device" by choosing [Online] [Debug] [Device test] and then click
on "FORCE ON".
2) If the connection between the output module and external device is
properly performed, the indicator lamp corresponding to the external
device "Y00" is lit.
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......