12 - 31 12 - 31
12 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL STATIONS
12.3.4 Creating a program
This section shows the program to be used for communication between the master
and local stations. The following diagram shows the relationship between the devices
of the master station programmable controller CPU and the devices of the local station
programmable controller CPU.
The shaded areas indicate the devices that are actually used.
[Remote input (RX) and remote output (RY)]
Master station
programmable
controller CPU
The last two bits cannot be used for communication between the master and local stations.
Ver.1 compatible
buffer memory
RY00F to RY000
RY01F to RY010
RY02F to RY020
RY03F to RY030
RY04F to RY040
RY05F to RY050
RX00F to RX000
RX01F to RX010
RX02F to RX020
RX03F to RX030
RX04F to RX040
RX05F to RX050
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y107D to Y1070
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X107D to X1070
Ver.2compatible local station
(station number 5: occupies 2 stations: double)
Ver.1compatible local station
(station number 1: occupies 4 stations)
Master station
RY06F to RY060
RY07F to RY070
RX06F to RX060
RX07F to RX070
Y105F to Y1050
Y106F to Y1060
X105F to X1050
X106F to X1060
RX00F to RX000
RX01F to RX010
RX02F to RX020
RX03F to RX030
RX04F to RX040
RX05F to RX050
RY00F to RY000
RY01F to RY010
RY02F to RY020
RY03F to RY030
RY04F to RY040
RY05F to RY050
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X107D to X1070
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y107D to Y1070
RX06F to RX060
RX07F to RX070
RY06F to RY060
RY07F to RY070
X105F to X1050
X106F to X1060
Y105F to Y1050
Y106F to Y1060
RX08F to RX080
RX09F to RX090
RX0AF to RX0A0
RX0BF to RX0B0
X150F to X1T500
X151F to X1510
X152F to X1520
X155D to X1550
RX0CF to RX0C0
RX0DF to RX0D0
X153F to X1530
X154F to X1540
RY08F to RY080
RY09F to RY090
RY0AF to RY0A0
RY0BF to RY0B0
Y150F to Y1500
Y151F to Y1510
Y152F to Y1520
Y155D to Y1550
RY0CF to RY0C0
RY0DF to RY0D0
Y153F to Y1530
Y154F to Y1540
RY00F to RY000
RY01F to RY010
RY02F to RY020
RY03F to RY030
RY04F to RY040
RY05F to RY050
RX00F to RX000
RX01F to RX010
RX02F to RX020
RX03F to RX030
RX04F to RX040
RX05F to RX050
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y107D to Y1070
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X107D to X1070
RY06F to RY060
RY07F to RY070
RX06F to RX060
RX07F to RX070
Y105F to Y1050
Y106F to Y1060
X105F to X1050
X106F to X1060
RY06F to RY060
RY07F to RY070
RY08F to RY080
RY09F to RY090
Y150F to Y1500
Y151F to Y1510
Y152F to Y1520
Y155D to Y1550
RY0AF to RY0A0
RY0BF to RY0B0
Y153F to Y1530
Y154F to Y1540
RX06F to RX060
RX07F to RX070
RX08F to RX080
RX09F to RX090
X150F to X1500
X151F to X1510
X152F to X1520
X155D to X1550
RX0AF to RX0A0
RX0BF to RX0B0
X153F to X1530
X154F to X1540
Local station
programmable
controller CPU
Ver.1 compatible
buffer memory
Local station
programmable
controller CPU
Ver.2 compatible
buffer memory
Ver.2 compatible
buffer memory
Содержание L26CPU-BT
Страница 1: ......
Страница 2: ......
Страница 7: ...A 5 A 5 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Страница 32: ...3 5 3 5 3 SPECIFICATIONS ...
Страница 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Страница 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Страница 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Страница 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Страница 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Страница 139: ...8 33 8 33 8 FUNCTIONS ...
Страница 151: ...8 45 8 45 8 FUNCTIONS ...
Страница 243: ...11 6 11 6 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS Set parameters as follows ...
Страница 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Страница 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Страница 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Страница 324: ...15 3 15 3 15 TROUBLESHOOTING 1 When the master station RUN LED is off 2 Common module check procedure ...
Страница 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Страница 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Страница 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Страница 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Страница 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Страница 439: ...App 75 App 75 APPENDIXES MEMO ...
Страница 447: ......
Страница 448: ......
Страница 449: ......