6 OPTIONS AND PERIPHERAL EQUIPMENT
6.2 Regenerative option
165
6
*1 Load torque converted into equivalent value on servo motor shaft TL can be calculated with the following formula. T
L
= {(F
C
+ (
μ
× W
L
×
g)) ×
Δ
S} / (2000 ×
π
×
η
)
*2 Load moment of inertia converted into equivalent value on servo motor shaft JL can be calculated with the following formula. J
L
= J
L1
+
J
L2
+ J
L3
J
L1
is the load moment of inertia of the moving part, J
L2
is the load moment of inertia of the ball screw, and J
L3
is the load
moment of inertia of the coupling. J
L1
and J
L2
can be calculated with the following formulas. J
L1
= W
L
× (
Δ
S / (20 ×
π
))
2
J
L2
= {(
π
×
0.0078 × (L
B
/ 10)) / 32} × (D
B
/ 10)
4
From the calculation results in (1) to (8), find the absolute value (Es) of the sum total of negative energies.
■
Losses of servo motor and servo amplifier in regenerative mode
The following table lists the efficiencies and other data of the servo motor and servo amplifier in the regenerative mode.
Inverse efficiency (
η
m
): Efficiency including some efficiencies of the servo motor and servo amplifier when rated (regenerative)
torque is generated at rated speed. Efficiency varies with the speed and generated torque. Because the characteristics of the
electrolytic capacitor change with time, allow inverse efficiency of approximately 10 % higher than those shown above.
Capacitor charging (Ec): Energy charged into the electrolytic capacitor in the servo amplifier
Regenerative
power
Torque T applied to servo motor [N•m]
Energy E [J]
(1)
(2)
T
2
= T
L
E
2
= 0.1047 • N • T
2
• t
1
(3)
(4), (8)
T
4
, T
8
= 0
E
4
, E
8
= 0 (No regeneration)
(5)
(6)
T
6
= T
L
E
6
= 0.1047 • N • T
6
• t
3
(7)
Servo amplifier
Inverse efficiency [%]
Capacitor charging [J]
MR-J5W2-22G_
85
17
MR-J5W2-44G_
90
21
MR-J5W2-77G_
90
44
MR-J5W2-1010G_
90
44
MR-J5W3-222G_
85
21
MR-J5W3-444G_
90
31
(J
L
/
η
+ J
M
) • N
9.55 • 10
4
t
psa1
1
•
T
1
=
+ T
L
2
0.1047
E
1
=
• N • T
1
• t
psa1
-(J
L
•
η
+ J
M
) • N
9.55 • 10
4
t
psd1
1
•
T
3
=
+ T
L
2
0.1047
E
3
=
• N • T
3
• t
psd1
(J
L
/
η
+ J
M
) • N
9.55 • 10
4
t
psa2
1
•
T
5
=
+ T
L
2
0.1047
E
5
=
• N • T
5
• t
psa2
-(J
L
•
η
+ J
M
) • N
9.55 • 10
4
t
psd2
1
•
T
7
=
+ T
L
2
0.1047
E
7
=
• N • T
7
• t
psd2
Содержание Melservo-J5 MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Страница 445: ......