3 SIGNALS AND WIRING
3.5 Signal (device) explanation
81
3
■
ALMWNG (Malfunction/Warning)
When an alarm occurs, ALMWNG turns off.
When a warning occurs (except for [AL. 09F Battery warning]), ALMWNG turns on and off repeatedly approximately every 1 s.
When neither an alarm nor a warning is occurring, ALMWNG will turn on in 2.5 s to 3.5 s after power-on.
■
BW9F (AL9F warning)
When [AL. 9F Battery warning] occurs, BW9F turns on.
In the absolute position detection system with a battery-less ABS encoder, BW9F is always off.
■
PENS (command pulse train input permitted)
While the command pulse train input can be received, PENS is on.
In addition, if PEN has not been assigned to the input device, PENS is on.
Available on servo amplifiers with firmware version A5 or later.
Содержание Melservo-J5 MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Страница 445: ......