6 OPTIONS AND PERIPHERAL EQUIPMENT
6.4 FR-XC multifunction regeneration converter
187
6
Wiring and peripheral options
Wire size
Selection conditions of wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction requirements: Single wire set in midair
■
Between P/+ to P4 and N/- to N-
The table below shows the wire sizes used for connecting the FR-XC and servo amplifier.
■
Grounding
The table below shows the grounding wire sizes for the FR-XC. Use the shortest size wire possible.
Total capacity of servo amplifiers [kW]
Wire size [mm
2
]
200 V class
1 or less
2 (AWG 14)
2
3.5 (AWG 12)
3.5
5.5 (AWG 10)
5
5.5 (AWG 10)
7
8 (AWG 8)
11
14 (AWG 6)
15
22 (AWG 4)
18.5
38 (AWG 2)
22
50 (AWG 1/0)
27.5
50 (AWG 1/0)
30
60 (AWG 2/0)
37
80 (AWG 3/0)
45
100 (AWG 4/0)
55
100 (AWG 4/0)
Multifunction regeneration converter
Wire size [mm
2
]
Rated capacity of multifunction
regeneration converter
≥
Total capacity of
connected servo amplifiers × 2
Rated capacity of multifunction
regeneration converter < Total capacity of
connected servo amplifiers × 2
FR-XC-7.5K
8 (AWG 8)
8 (AWG 8)
FR-XC-11K
8 (AWG 8)
14 (AWG 6)
FR-XC-15K
8 (AWG 8)
22 (AWG 4)
FR-XC-22K
22 (AWG 4)
38 (AWG 2)
FR-XC-30K
22 (AWG 4)
38 (AWG 2)
FR-XC-37K
38 (AWG 2)
60 (AWG 2/0)
FR-XC-55K
38 (AWG 2)
80 (AWG 3/0)
Содержание Melservo-J5 MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Страница 445: ......