264
7 ABSOLUTE POSITION DETECTION SYSTEM
7.1 Outline
System architecture
The following shows the architecture of the absolute position detection system.
When connecting the battery-less absolute position encoder
When connecting the battery backup type absolute position encoder
For each battery connection, refer to the following.
Servo parameter setting [G] [WG]
Set [Pr. PA03 Absolute position detection system] to "1" (enabled (absolute position detection system)).
Servo parameter setting [A]
Set [Pr. PA03 Absolute position detection system] to "1" (enabled (absolute position detection system by DIO)).
Homing
After the absolute position detection system is enabled, [AL. 025 Absolute position erased] occurs at the initial startup. Then,
ABSV (Absolute position undetermined) turns on. Refer to "CONTROL MODE" in the following manual and perform homing.
MR-J5 User's Manual (Function)
CN1_
CN2
CN4
Controller
Servo amplifier
Servo motor
Do not connect anything.
CN1_
CN2
CN4
Controller
Servo amplifier
Battery
Servo motor
Содержание Melservo-J5 MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Страница 445: ......