2 INSTALLATION
2.2 Keeping out foreign materials
29
2
Other precautions
When using heat generating equipment such as the regenerative option, install it with full consideration of heat generation so
that the servo amplifier is not affected.
Mount the servo amplifier on a perpendicular wall in the correct vertical direction.
2.2
Keeping out foreign materials
When drilling the cabinet for assembly, prevent drill chips and wire fragments from entering the servo amplifier.
Prevent foreign matter such as oil, water, and metallic dust from entering the servo amplifier through cooling fans installed in
openings in the cabinet or on the ceiling.
When installing the cabinet in a place where toxic gas, dirt, and dust exist, conduct an air purge (force clean air into the
cabinet from outside to make the internal pressure higher than the external pressure) to prevent such materials from entering
the cabinet.
2.3
Cable stress
• The method used to clamp the cable must be fully examined so that bending stress and cable's own weight stress are not
applied to the cable connection.
• When used for applications where the servo motor moves, fix the cable (encoder, power supply, brake) with gentle slack
from the connecting part of the connector to prevent stress from being applied to the connecting part of the servo motor
connector. Use the optional motor cable/encoder cable within the flex life range.
• Prevent the cable insulator from being cut by sharp chips or from touching and rubbing against the machine corners.
• Prevent the cables from getting stepped on by workers or run over by vehicles.
• If installing the servo motor that moves on a machine, make the bend radius as large as possible. Refer to the following for
the flex life.
Precautions
• The cables should not be damaged, stressed, loaded, or pinched.
2.4
Fan unit replacement procedure
The fan unit is composed of a cooling fan and its cover. If replacing the cooling fan, replace the entire fan unit.
In addition, shut off the power supply before replacing the fan unit.
List of applicable fan units
Servo amplifier
Model of fan unit to be replaced
MR-J5-70_
MR-J5-100_
MR-J5-FAN1
MR-J5-200_
MR-J5-350_
MR-J5-FAN2
MR-J5-500_
MR-J5-FAN3
MR-J5-700_
MR-J5-FAN4
MR-J5W2-44G_
MR-J5W-FAN1
MR-J5W2-77G_
MR-J5W2-1010G_
MR-J5W-FAN3
MR-J5W3-222G_
MR-J5W3-444G_
MR-J5W-FAN2