11 USING A DIRECT DRIVE MOTOR
11.4 Basic functions
387
11
Servo control error reset by controller reset [G] [WG]
When [Pr. PL04.3 [AL. 042 Servo control error] detection controller reset condition selection] is set to "1" (reset enabled), [AL.
042.1 Servo control error based on position deviation], [AL. 042.2 Servo control error based on speed deviation], and [AL.
042.3 Servo control error based on torque/thrust deviation] can be canceled by resetting the controller. When [Pr. PL04.3] is
"0" (reset disabled (reset by powering off/on or software reset enabled)), [AL. 042.1], [AL. 042.2], and [AL. 042.3] can be
canceled only by cycling the servo amplifier power or resetting the software.
Servo parameter
Description
PL04.3
[AL. 042 Servo control error] detection controller reset condition selection
0: Reset disabled (reset by powering off/on or software reset enabled)
1: Reset enabled
Initial value: 0 (reset disabled)
Содержание Melservo-J5 MR-J5 Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Страница 445: ......