3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.5 Control Equipment Side Setting
3.5 Control Equipment Side Setting
POINT
POINT
POINT
AZBIL control equipment
For details of AZBIL control equipment, refer to the
following manual.
User's Manual of the AZBIL control equipment
3.5.1
Connecting to DMC10
Communication settings
Make the communication settings by operating the
Smart Loader Package (SLP-D10) of the temperature
controller.
*1
Adjust the settings with GOT settings.
*2
Set to CPL.
*3
Do not set to "0".
*4
Select the station address without overlapping with that of
other units.
Station address setting
Set the station address using the rotary switch for the
station address.
3.5.2
Connecting to SDC40A/40B/
40G
Communication settings
Make the communication settings by operating the key
of the temperature controller.
*1
The transmission speed setting must be consistent with that
of the GOT side.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
3.5.3
Connecting to SDC15,
SDC25/26 or SDC35/36
Communication settings
Make the communication settings by operating the key
or Smart Loader Package (SLP-C35) of the
temperature controller.
*1
The transmission speed setting must be consistent with that
of the GOT side.
*2
Set to CPL.
*3
Do not set to "0".
*4
Select the station address without overlapping with that of
other units.
Model name
Refer to
Control
equipment
DMC10
SDC15, SDC25/26, SDC35/36
SDC20/21
SDC30/31
SDC40A/40B/40G
DMC50
SDC45/46
CMS, CMF015
CML, CMF050
MQV
MPC
PBC201-VN2
MVF
AUR350C, AUR450C
RX
CMC10B
AHC2001 CPU module
AHC2001 SCU module
Interface
converter
CMC10L
Item
Set value
Transmission speed
*1
9600bps, 19200bps
Communication mode
*2
CPL
Data bit
8bits
Parity bit
*1
Even, none
Stop bit
2bits
Communication minimum
response time
1ms, 10ms, 100ms, 200ms
Station address
*3*4
0 to F
Item
Set value
Transmission speed
*1
9600bps
Data Bit
8bits
Parity bit
*1
Even, none
Stop bit
1bit, 2bits
Station address
*2*3
0 to 127
Item
Set value
Transmission speed
*1
9600bps, 19200bps
Communication mode
*2
CPL
Data bit
*1
7bits, 8bits
Parity bit
*1
Odd, even, none
Stop bit
*1
1bit, 2bits
Communication minimum
response time
1 to 250ms
Station address
*3*4
0 to 127
Rotary switch
for the station address
Front of the temperature
controller body
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......