3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.5 Control Equipment Side Setting
3 - 49
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CON
N
EC
TI
O
N
T
O
AZBIL
C
O
N
T
ROL
EQU
IP
M
EN
T
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
3.5.4
Connecting to SDC20/21,
SDC30/31
Communication settings
Make the communication settings by operating the key
of the temperature controller.
*1
The transmission speed setting must be consistent with that
of the GOT side.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
3.5.5
Connecting to CMC10L
Communication settings
Make the communication settings by operating the DIP
switch of the Interface converter
*1
The transmission speed setting must be consistent with that
of the GOT side.
*2
The sum of data length, parity bit and stop bit
Settings by switch
(1) Setting DIP switches
(a) Transmission speed settings
(b) Frame length settings
(c) Connecting terminating resistors
(2) Mode selector switch settings
Set the switch to “TERMINAL”.
Item
Set value
Transmission speed
*1
9600bps
Data bit
8bits
Parity bit
Disable
Stop bit
2bits
Station address
*2*3
0 to 127
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Frame length
*2
9 to 15bits
DIP switch
Mode selector
switch
Front view of CMC10L body
Rear view of CMC10L body
Transmission
speed (bps)
Switch No.
1
2
3
9600
ON
OFF
ON
19200
OFF
ON
ON
38400
ON
ON
ON
Frame length
Switch No.
4
5
6
8bits
OFF
OFF
OFF
9bits
ON
OFF
OFF
10bits
OFF
ON
OFF
11bits
ON
ON
OFF
12bits
OFF
OFF
ON
13bits
ON
OFF
ON
14bits
OFF
ON
ON
15bits
ON
ON
ON
Terminating
resistor
Switch No.
8
Enable
ON
Disable
OFF
Set these
switches
Set these
switches
Set these
switches
TERMINAL
(CROSS)
MODEM
(STRAIGHT)
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......