3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.5 Control Equipment Side Setting
3 - 53
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CON
N
EC
TI
O
N
T
O
AZBIL
C
O
N
T
ROL
EQU
IP
M
EN
T
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
3.5.17 Connecting to AHC2001 CPU
module
Communication settings
Make the communication settings by operating the key
of the temperature controller or Smart Loader Package
(SLP-D50 or SLP-H21).
*1
The transmission speed setting must be consistent with that
of the GOT side.
*2
Set to 1: CPL.
*3
Select the station address without overlapping with that of
other units.
*4
Although the device address range of AHC2001 is 1 to 127,
use the device setting range of DMC50 of 1 to 15.
3.5.18 Connecting to AHC2001 SCU
module
Communication settings
Make the communication settings by operating the key
of the temperature controller or Smart Loader Package
(SLP-D50 or SLP-H21).
*1
Adjust the settings of transmission speed, data length, parity
bit, and stop bit with that of the GOT.
*2
Set to 2: CPL.
*3
Set to 0: Half-duplex.
3.5.19 Station number setting
Set each station number so that no station number
overlaps.
The station number can be set without regard to the cable
connection order. There is no problem even if station
numbers are not consecutive.
(1) Direct specification
When setting the device, specify the station number of
the control equipment of which data is to be changed.
*1
Although the station number range of AHC2001 is 1 to 127,
use the station number range of DMC50 of 1 to 15.
(2) Indirect specification
When setting the device, indirectly specify the station
number of the inverter of which data is to be changed
using the 16-bit GOT internal data register (GD10 to
GD25).
When specifying the station No. from the following table
on GT Designer3, the value of GD10 to GD25
compatible to the station No. specification will be the
station No. of the control equipment.
*1
Although the station number range of AHC2001 is 1 to 127,
use the station number range of DMC50 of 1 to 15.
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps, 57600bps
Mode
*2
1: CPL
Data length
8bits (fixed)
Parity bit
Even (fixed)
Stop bit
1bit (fixed)
Station address
*3
1 to 15
*4
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Protocol setting
*2
2: CPL
Data length
*1
7bits, 8bits
Parity bit
*1
0: None, 1: Even, 2: Odd
Stop bit
*1
1bit, 2bits
Half-duplex/Duplex
*3
0: Half-duplex
Spacing transmission
0 (fixed)
Model name
Specification
range
SDC40A/40B/40G, SDC15, SDC25/26, SDC35/36,
SDC20/21, SDC30/31
CML, CMF050, MQV, MPC
1 to 127
PBC201-VN2
1 to 126
SDC45/46
1 to 120
CMS, CMF015, CMC10B
1 to 99
RX
1 to 32
DMC10, DMC50, MVF, AUR350C, AUR450C, AHC2001
*1
1 to 15
Specification
station No.
Compatible
device
Setting range
DMC50
AHC2001
Other
than
DMC50
100
200
GD10
1 to 127:
For SDC40A/40B/40G,
SDC15, SDC25/26,
SDC35/36, SDC20/21,
SDC30/31, CML,
CMF050, MQV, MPC
1 to 126: PBC201-VN2
1 to 120: SDC45/46
1 to 99:
CMS, CMF015, CMC10B
1 to 32:
RX
1 to 15:
DMC10, DMC50, MVF,
AUR350C, AUR450C,
AHC2001
*1
For the setting other than the above,
error (dedicated device is out of
range) will occur.
101
201
GD11
102
202
GD12
103
203
GD13
104
204
GD14
105
205
GD15
106
206
GD16
107
207
GD17
108
208
GD18
109
209
GD19
110
210
GD20
111
211
GD21
112
212
GD22
113
213
GD23
114
214
GD24
115
215
GD25
Station
No.3
GOT
Station
No.10
Station
No.1
Station
No.15
Station
No.6
Examples of station number setting
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......