5 - 14
5. CONNECTION TO OMRON TEMPERATURE CONTROLLER
5.5 Temperature Controller Side Setting
5.5 Temperature Controller Side Setting
POINT
POINT
POINT
OMRON temperature controller
For details of OMRON temperature controller, refer to
the following manual.
User's Manual of the OMRON temperature
controller
5.5.1
Connecting E5AN, E5EN,
E5CN, E5GN
Set the communication data by operating the key of the
temperature controller.
*1
Adjust the settings with GOT settings.
*2
Select the communication unit No. without overlapping with
that of other units.
*3
When changing the device values of the temperature
controller from the GOT, turn ON CMWT (Communications
writing) in advance.
5.5.2
Connecting E5ZN
Set the communication data by operating the key of the
temperature controller.
*1
Adjust the settings with GOT settings.
*2
Select the communication unit No. without overlapping with
that of other units.
*3
When changing the device values of the temperature
controller from the GOT, turn ON CMWT (Communications
writing) in advance.
5.5.3
Connection to interface
converter (K3SC-10)
Communication settings
Make the communication settings by operating the DIP
switch of the temperature controller.
*1
Adjust the settings with GOT settings.
*2
Set to “Without”.
Settings by DIP switch
(1) Transmission speed settings
Model name
Refer to
Temperature controller
E5AN, E5EN, E5CN, E5GN
E5ZN
Interface converter
K3SC-10
Item
Set value
Protocol
CompoWay/F (Sysway)
Transmission speed
*1
9600bps, 19200bps
Data bit
*1
8 bits, 7 bits
Parity bit
*1
Odd, Even, None
Stop bit
*1
1bit, 2bits
Communication unit No.
*2
0 to 99
CMWT (Communications writing)
*3
ON
Item
Set value
Transmission speed
*1
9600bps, 38400bps
Data bit
*1
8 bits, 7 bits
Parity bit
*1
Odd, Even, None
Stop bit
*1
1bit, 2bits
Communication unit No.
*2
0 to 15
CMWT (Communications writing)
*3
ON
Item
Set value
Transmission speed
*1
19200bps, 38400bps
Data bit
*1
7 bits, 8 bits
Parity bit
*1
Odd, Even, None
Stop bit
*1
1bit, 2bits
Communication Type
RS-232
RS485
Echo back
*2
With, Without
Transmission
speed (bps)
Switch No.
1
2
3
1200
ON
OFF
OFF
2400
OFF
ON
OFF
4800
ON
ON
OFF
9600
OFF
OFF
OFF
19200
ON
OFF
ON
38400
OFF
ON
ON
Terminal block
for RS-422/485
communication
Terminal block
for RS-232
communication
Front of K3SC-10 body
Inside of K3SC-10 body
(When removing the front cover)
DIP switch
ON
SW
Set these
switches.
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......