2 - 30
2. CONNECTION TO IAI ROBOT CONTROLLER
2.6 Device Range that Can Be Set
(2) Status (S) (Bit device)
The following shows device numbers which can be set for the status and the corresponding device contents.
Status
Area name
Description
Abbreviation
0000 to 00FF
- (Reserved for system)
0100
Device status register 1 (DSS1)
EMG status
EMGS
0101
Safety speed enabled status
SFTY
0102
Controller ready status
PWR
0103
Servo ON status
SV
0104
Missed work in push-motion operation
PSFL
0105
Major failure status
ALMH
0106
Minor failure status
ALML
0107
Absolute error status
ABER
0108
Brake forced-release status
BKRL
0109
Cannot be used
010A
Pause status
STP
010B
HomingHome return status
HEND
010C
Positioning completion Position complete
status
PEND
010D to 010F
Cannot be used
0110
Device status register 2 (DSS2)
Cannot be used
0111
Cannot be used
0112
Load output judgment status
LOAD
0113
Torque level status
TRQS
0114
Teaching mode status
MODS
0115
Position-data load command status
TEAC
0116
Jog+ status
JOG+
0117
Jog- status
JOG-
0118
Completed positionPosition complete 7
PE7
0119
Completed positionPosition complete 6
PE6
011A
Completed positionPosition complete 5
PE5
011B
Completed positionPosition complete 4
PE4
011C
Completed positionPosition complete 3
PE3
011D
Completed positionPosition complete 2
PE2
011E
Completed positionPosition complete 1
PE1
011F
Completed positionPosition complete 0
PE0
0120
Expansion device status
register
(DSSE)
Emergency stop status
EMGP
0121
Motor voltage low status
MPUV
0122
Operation mode status
RMDS
0123
Cannot be used
0124
HomingHome return status
GHMS
0125
Push-motion operation in progress
PUSH
0126
Excitation detection status
PSNS
0127
PIO/Modbus switching status
PMSS
0128
Cannot be used
0129
Cannot be used
012A
Moving signal
MOVE
(Continued to next page)
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......