15. CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC
15.6 Device Range that Can Be Set
15 - 21
9
CONN
E
C
TION
T
O
S
H
ARP PLC
10
C
O
NN
ECTI
ON
T
O
SHI
N
KO
TECHN
OS IN
DIC
ATI
NG
C
O
NT
ROLLE
R
11
CONNECTION T
O
CH
INO
CONTROLLE
R
12
CONNECTION T
O
T
O
SHI
B
A
PL
C
13
CONNECTION T
O
T
O
SH
IB
A M
A
C
H
IN
E
PLC
14
CONNECTION T
O
P
A
NA
SONIC S
E
R
V
O
A
M
PL
IF
IE
R
15
CONNE
CTION T
O
PA
NA
SONIC
INDUSTRI
AL
DE
VI
CES
SU
NX
PLC
15.6.1 Panasonic Industrial Devices SUNX PLC (Panasonic MEWNET-FP)
*1
The above device range is for the case where FP10SH is used.
For FP0, FP1, FP2, FP3, FP5, FP-10(S), or FP-M, device ranges are different in individual CPUs.
*2
Writing to device is not allowed.
*3
Only those devices that have been assigned to I/O contacts by peripheral software can be used.
*4
The device points of the timer and counter differs depending on the head numbers of the counter set by the value of the system
register (No. 5).
*5
This device does not exist in FP0, FP1, and FP-M.
*6
When FP2SH is used, one bank of "32765 3 banks" can be monitored.
*7
This is not supported by GT10.
Device name
Setting range
Device No.
representation
B
it de
vi
ce
Input relay (X)
*2*3
X0000
to
X511F
D
Hexadecimal
Output relay (Y)
*3
Y0000
to
Y511F
Internal relay (R)
R0000
to
R886F
Special relay (R)
*2
R9000
to
R911F
Link relay (L)
*5
L0000
to
L639F
Timer contact (T)
*2*4
T0
to
T3071
Decimal
Counter contact (C)
*2*4
C0
to
C3071
Word device bit
*7
Specified bit of the following word devices
(except input relay, output relay, internal relay, special relay
and link relay)
-
W
o
rd
de
vi
ce
Input relay (WX)
*2
WX000
to
WX511
Decimal
Output relay (WY)
WY000
to
WY511
Internal relay (WR)
WR000
to
WR886
Special relay (WR)
*2
WR900
to
WR911
Link relay (WL)
WL000
to
WL639
Timer/Counter (Elapsed value) (EV)
*4
EV0
to
EV3071
Timer/Counter (Set value) (SV)
*4
SV0
to
SV3071
Data register (DT)
DT0
to
DT10239
Special data register (DT)
DT0
to
DT32764
DT90000
to
DT90511
Link register (LD)
*5
LD0
to
LD8447
File register (FL)
*5*6
FL0
to
FL32764
Bit device word
*7
Converting bit devices into word
(Except Timer contact and Counter contact)
-
*1
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......