4. CONNECTION TO OMRON PLC
4.3 Ethernet Connection
4 - 39
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CONNECTION T
O
AZBI
L C
O
NTR
O
L
EQUI
PMENT
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
4.3.3
PLC side setting
POINT
POINT
POINT
OMRON PLC
For the communication between OMRON PLC and GOT, use the FINS communication.
For the FINS communication, the node must be specified according to the realm of FINS. However, for the
Ethernet network, the data transfer according to the IP address is required.
• Automatic conversion method (dynamic)
• Automatic conversion method (static)
• IP address table conversion method
• Combined method
The following four methods are available for converting the FINS node address to the IP address.
For details of OMRON PLCs, refer to the following manual.
OMRON PLC user's Manual
Communication settings
For the PLC communication setting, set with a software for programming apparatus (CX-Programmer Ver.3.20 or
later).
(1) CX-Programmer setting
*1
Set the same [IP address] and [FINS UDP Port] settings as that of [IP address] and [Port No.] of the GT Designer3 Ethernet
setting.
*2
The Node IP Address dynamically change function is available only when the Ethernet module to be used is Ver.1.3 or later.
For the setting, set in the module setting of CX-ProgrammerVer.5.0 or later or in the WEB function.
For details of Node IP Address dynamically change, refer to the following manual.
OMRON PLC user's Manual
*3
Set the same lowermost bit of the [IP address] setting as that of the node setting switch of the module.
*4
Set the same [GOT Port No. (Communication)] In Communication detail settings as that of [Port No.] of the Ethernet setting.
*5
Set the same lowermost bit of the [GOT IP address] in Communication detail settings as that of [GOT PLC No.].
*6
Set the same lowermost bit of the [GOT IP address] and [GOT PLC No.] in Communication detail settings of GT Designer3 as
that of [IP address table].
Item
Setting range
Automatic conversion method
(dynamic)
*4
Automatic conversion
method (static)
*4*5
IP address table method
*4*6
Combined method
*4*6
Ethernet
module
CPU
highly-
functional
module
Global
All 1 (Default)
All 1 (Default)
All 1 (Default)
All 1 (Default)
IP address
*1
[192]. [168]. [0]. [1]
*3
[192]. [168]. [0]. [1]
*3
[192]. [168]. [0]. [1]
[192]. [168]. [0]. [1]
Subnet Mask
[255]. [255]. [255]. [0]
[255]. [255]. [255]. [0]
[255]. [255]. [255]. [0]
[255]. [255]. [255]. [0]
FINS UDP port
*1
9600
9600
9600
9600
IP address
conversion
Automatic conversion
method (dynamic)
Automatic conversion
method (static)
IP address table method
Combined method
IP address table
-
-
10 [192]. [168]. [0]. [1]
11 [192]. [168]. [0]. [18]
10 [192]. [168]. [0]. [1]
Transmission
speed
Automatic detection (Default)
Automatic detection (Default)
Automatic detection (Default)
Automatic detection (Default)
Node IP Address
dynamically
change
*2
Change dynamically
(Default)
Change dynamically
(Default)
Change dynamically
(Default)
Change dynamically
(Default)
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......