6. CONNECTION TO KEYENCE PLC
6.4 Device Range that Can Be Set
6 - 21
1
P
R
EP
ARA
T
OR
Y
P
R
OCEDURES
FOR
MONIT
O
R
ING
2
C
O
NNECTION T
O
IAI
ROBO
T
CO
N
T
RO
L
L
E
R
3
CONNECTION T
O
AZBI
L C
O
NTR
O
L
EQUI
PMENT
4
CONNECTION T
O
OMRON PLC
5
CONNECTI
O
N T
O
OMRO
N TEMPERA
TURE
CONTROL
LE
R
6
CONNECTION T
O
KE
YENCE PL
C
7
CONNE
C
T
ION T
O
KO
YO
EI
PLC
8
CONN
E
CT
ION T
O
JT
EK
T PL
C
6.4.1
KV-700/1000/3000/5000
*1
Monitoring or writing is not possible in the continuous device
designation mode.
*2
Monitoring by GOT is possible only when a device is used in
the sequence program.
*3
When writing, only the reset of the contact is possible.
*4
Only 32-bit (2-word) designation is allowed.
*5
Only reading is possible.
*6
Monitoring or writing to continuous devices is not possible.
*7
This is not supported by GT10.
*8
With KV-3000 and KV-5000, Z devices cannot be specified
as 32-bit (2 words) data.
Use DZ devices.
Device name
Setting range
Device
No.
represen
tation
Bit d
e
vice
Relay (...)
..00000 to ..99915
Decimal
Internal auxiliary relay (MR)
MR00000 to MR99915
Latch relay (LR)
LR00000 to LR99915
Control relay (CR)
CR0000 to CR3915
Link relay (B)
*2
B0000 to B3FFF
Hexadec
imal
Work relay (VB)
*2
VB0000 to VB3FFF
Timer (Contact) (T)
*1*2
T0000 to T3999
Decimal
Counter (Contact) (C)
*1*2
C0000 to C3999
High-speed counter
comparator
(Contact) (CTC)
*2*3*6
CTC0 to CTC3
Word device bit
*7
Specified bit of the following word
devices
data memory
extension data memory
extension data memory 2
file register
link register
-
W
o
rd
devi
ce
Timer (Current value) (TC)
*2*4
TC0000 to TC3999
Decimal
Timer (Set value) (TS)
*2*4
TS0000 to TS3999
Counter (Current value)
(CC)
*2*4
CC0000 to CC3999
Counter (Set value) (CS)
*2*4
CS0000 to CS3999
High-speed counter
(Current value) (CTH)
*2*4
CTH0 to CTH1
High-speed counter
comparator
(Set value) (CTC)
*2*4
CTC0 to CTC3
Data memory (DM)
DM00000 to DM65534
Extension data memory (EM)
EM00000 to EM65534
Extension data memory 2 (FM)
FM00000 to FM32767
File register (ZF)
ZF000000 to ZF032767
ZF032768 to ZF065535
ZF065536 to ZF098303
ZF098304 to ZF131071
Link register (W)
W0000 to W3FFF
Hexadec
imal
Control memory (CM)
CM00000 to CM11998
Decimal
Temporary data memory (TM)
TM000 to TM511
Work memory (VM)
VM00000 to VM59999
Index register (Z)
*8
Z1 to Z12
Index register (DZ)
DZ01 to DZ12
Digital trimmer (TRM)
*4*5
TRM0 to TRM7
Bit device word
*7
Converting the following bit
devices to words
relay
internal auxiliary relay
latch relay
control relay
link relay
work relay
-
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......