Specifications
Common specifications
FR-F800
8 - 11
Available only for the standard model.
This protective function is not available in the initial status.
Temperature applicable for a short time, e.g. in transit.
For the installation at an altitude above 1,000 m up to 2,500 m, derate the rated current 3% per
500 m.
!
2.9 m/s² for the FR-F840-04320(185K) or higher.
Available only for the FR-F800-E series.
$
Not available for the FR-F800-E series.
Indic
a
tion
For meter
Pulse train
output
(FM type)
Max. 2.4 kHz: one terminal (output frequency)
The monitored item can be changed using Pr. 54 "FM/CA terminal function selection".
Current
output
(CA type)
Max. 20 mA DC: one terminal (output current)
The monitored item can be changed using Pr. 54 "FM/CA terminal function selection".
Voltage
output
Max. 10 V DC: one terminal (output voltage)
The monitored item can be changed using Pr. 158 "AM terminal function selection".
Operation
panel
(FR-DU08)
Operating
status
Output frequency, output current, output voltage, frequency setting value
The monitored item can be changed using Pr. 52 "Operation panel main monitor selection".
Fault record
Fault record is displayed when a fault occurs. Past 8 fault records and the conditions immediately before the
fault (output voltage/current/frequency/cumulative energization time/year/month/date/time) are stored.
Protective/
warning
function
Protective
function
Overcurrent trip during acceleration, overcurrent trip during constant speed, overcurrent trip during
deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during
constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic
thermal relay function), Motor overload trip (electronic thermal relay function), Heatsink overheat,
Instantaneous power failure
, Input phase loss
, Stall prevention stop, Loss of
synchronism detection
, Upper limit fault detection, Lower limit fault detection, Brake transistor alarm
detection
, Output side earth (ground) fault overcurrent, Output short circuit, Output phase loss, External
thermal relay operation
, Option fault, Communication option fault, Parameter
storage device fault, PU disconnection, Retry count excess
, CPU fault, Operation panel power supply short
circuit, RS-485 terminal power supply short circuit
, 24 V DC power fault, Abnormal output current detection
, Inrush current limit circuit fault
, Communication fault (inverter), Ethernet communication fault
Analog input fault, USB communication fault, Safety circuit fault, Overspeed occurrence
,
Pre-charge fault
, PID signal fault
, Internal circuit fault, User definition error in the PLC function
Warning
function
Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm
Electronic thermal relay function pre-alarm, PU stop, Parameter copy, Safety stop, Maintenance timer 1 to 3
USB host error, Operation panel lock
, Parameter write error, Copy operation error, 24 V
external power supply operation, Load fault warning, Emergency drive in operation
, Continuous operation
during communication fault, Ethernet communication fault
En
vironmen
t
Surrounding air
temperature
-10 °C to +50 °C (non-freezing) (LD rating)
-10 °C to +40 °C (non-freezing) (SLD rating)
Surrounding air humidity
With circuit board coating (conforming to IEC60721-3-3 3C2/3S2): 95% RH or less (non-condensing),
Without circuit board coating: 90% RH or less (non-condensing)
Storage temperature
-20 °C to +65 °C
Atmosphere
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Altitude/vibration
Maximum 1000 m above sea level
, 5.9 m/s
2
or less
at 10 to 55 Hz (directions of X, Y, Z axes)
Tab. 8-7:
Common specifications (2)
Содержание FR-F820-00046
Страница 2: ......
Страница 4: ......
Страница 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Страница 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Страница 874: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 900: ...Outline dimension drawings Specifications 8 26 ...
Страница 928: ...EC Declarations of Conformity Appendix A 28 A 6 EC Declarations of Conformity A 6 1 FR F820 FR F840 FR F842 series ...
Страница 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Страница 930: ...EC Declarations of Conformity Appendix A 30 ...
Страница 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Страница 932: ...EC Declarations of Conformity Appendix A 32 ...
Страница 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Страница 934: ...EC Declarations of Conformity Appendix A 34 ...
Страница 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Страница 936: ...EC Declarations of Conformity Appendix A 36 ...
Страница 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Страница 938: ...EC Declarations of Conformity Appendix A 38 ...
Страница 939: ......