Parameters
Ethernet communication (FR-F800-E)
FR-F800
5 - 611
Frequency command with sign (Pr. 541)
●
The start command (forward/reverse rotation) can be inverted by adding a plus or minus sign to
the value of the frequency command sent through the CC-Link IE Field Network Basic.
●
The Pr. 541 "Frequency command sign selection" setting is applied to the frequency command
from RWw1. (Refer to 5-619.)
●
Relationship between the start command and sign (Pr. 541 = "1")
Speed setting using
Pr. 37 and Pr. 144
Pr. 541
Sign
Setting range
Actual frequency command
Not used
0
Not used
0 to 59000
0 to 590.00 Hz
1
With
-32768 to 32767
(two's complement)
-327.68 to 327.67 Hz
With
0
Not used
0 to 65535
It depends on Pr. 37, and Pr. 144. (in 1
or 0.1 increments)
1
With
-32768 to 32767
(two's complement)
Tab. 5-328:
Setting the sign with Pr. 541
Start command
Sign of the frequency command
Actual run command
Forward rotation
+
Forward rotation
–
Reverse rotation
Reverse rotation
+
Reverse rotation
–
Forward rotation
Tab. 5-329:
Influence of the sign on the rotation direction
NOTE
When Pr. 541 = 1 (with sign):
●
When EEPROM write is specified with the RYE, write mode error (error code H01) will occur.
●
When concurrent execution of both RYD and RYE is enabled (when a value other than 0 is set in
Pr. 544) and both RYD and RYE are turned ON, RYD has precedence.
●
When power is turned ON (inverter reset), the initial setting status of the sign bit is "positive"
and the set frequency is "0 Hz". (The motor does not operate at the frequency set before turn-
ing OFF the power (inverter reset).)
●
When set frequency is written with the instruction code of HED and HEE, the sign of the fre-
quency command is not changed.
Содержание FR-F820-00046
Страница 2: ......
Страница 4: ......
Страница 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Страница 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Страница 874: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 900: ...Outline dimension drawings Specifications 8 26 ...
Страница 928: ...EC Declarations of Conformity Appendix A 28 A 6 EC Declarations of Conformity A 6 1 FR F820 FR F840 FR F842 series ...
Страница 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Страница 930: ...EC Declarations of Conformity Appendix A 30 ...
Страница 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Страница 932: ...EC Declarations of Conformity Appendix A 32 ...
Страница 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Страница 934: ...EC Declarations of Conformity Appendix A 34 ...
Страница 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Страница 936: ...EC Declarations of Conformity Appendix A 36 ...
Страница 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Страница 938: ...EC Declarations of Conformity Appendix A 38 ...
Страница 939: ......