![Mitsubishi Electric FR-F820-00046 Скачать руководство пользователя страница 188](http://html.mh-extra.com/html/mitsubishi-electric/fr-f820-00046/fr-f820-00046_instruction-manual_1811886188.webp)
Parameter List
Parameters
5 - 16
⎯
779
N014
Operation frequency during
communication error
0 to 590 Hz, 9999
0.01 Hz
9999
⎯
791
F070
Acceleration time in low-speed range
0 to 3600 s, 9999
0.1 s
9999
⎯
792
F071
Deceleration time in low-speed range
0 to 3600 s, 9999
0.1 s
9999
⎯
799
M520
Pulse increment setting for output
power
0.1, 1, 10, 100, 1000 kWh
0.1 kWh
1 kWh
⎯
800
G200
Control method selection
9, 20
1
20
Ad
ju
st
m
e
nt
f
u
n
ct
io
n
820
G211
Speed control P gain 1
0 to 1000%
1%
25%
821
G212
Speed control integral time 1
0 to 20 s
0.001 s
0.333 s
822
T003
Speed setting filter 1
0 to 5 s, 9999
0.001 s
9999
824
G213
Torque control P gain 1 (current loop
proportional gain)
0 to 500%
1%
50%
825
G214
Torque control integral time 1 (current
loop integral time)
0 to 500 ms
0.1 ms
40 ms
827
G216
Torque detection filter 1
0 to 0.1 s
0.001 s
0 s
828
G224
Parameter for manufacturer setting. Do not set.
830
G311
Speed control P gain 2
0 to 1000%, 9999
1%
9999
831
G312
Speed control integral time 2
0 to 20 s, 9999
0.001 s
9999
832
T005
Speed setting filter 2
0 to 5 s, 9999
0.001 s
9999
834
G313
Torque control P gain 2
0 to 500%, 9999
1%
9999
835
G314
Torque control integral time 2
0 to 500 ms, 9999
0.1 ms
9999
837
G316
Torque detection filter 2
0 to 0.1 s, 9999
0.001 s
9999
A
dditi
onal
fu
n
ct
io
n
849
T007
Analog input offset adjustment
0 to 200%
0.1%
100%
A
dd
itional func
tion
858
T040
Terminal 4 function assignment
0, 4, 9999
1
0
859
C126
Torque current/Rated PM motor current
0.01 A
9999
0 to 3600 A, 9999
860
C226
Second motor torque current/Rated PM
motor current
0.01 A
9999
0 to 3600 A, 9999
864
M470
Torque detection
0 to 400%
0.1%
150%
In
dica
ti
on
fun
c
tion
866
M042
Torque monitoring reference
0 to 400%
0.1%
150%
⎯
867
M321
AM output filter
0 to 5 s
0.01 s
0.01 s
⎯
868
T010
Terminal 1 function assignment
0, 4, 9999
1
0
⎯
869
M334
Current output filter
0 to 5 s
0.01 s
⎯
0.02 s
⎯
870
M440
Speed detection hysteresis
0 to 5 Hz
0.01 Hz
0 Hz
Pr
o
te
ct
iv
e
Fu
n
c
ti
o
n
s
872
H201
Input phase loss protection selection
0, 1
1
0
874
H730
OLT level setting
0 to 400%
0.1%
120%
110%
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (15)
Содержание FR-F820-00046
Страница 2: ......
Страница 4: ......
Страница 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Страница 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Страница 874: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 900: ...Outline dimension drawings Specifications 8 26 ...
Страница 928: ...EC Declarations of Conformity Appendix A 28 A 6 EC Declarations of Conformity A 6 1 FR F820 FR F840 FR F842 series ...
Страница 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Страница 930: ...EC Declarations of Conformity Appendix A 30 ...
Страница 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Страница 932: ...EC Declarations of Conformity Appendix A 32 ...
Страница 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Страница 934: ...EC Declarations of Conformity Appendix A 34 ...
Страница 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Страница 936: ...EC Declarations of Conformity Appendix A 36 ...
Страница 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Страница 938: ...EC Declarations of Conformity Appendix A 38 ...
Страница 939: ......