![Mitsubishi Electric FR-F820-00046 Скачать руководство пользователя страница 617](http://html.mh-extra.com/html/mitsubishi-electric/fr-f820-00046/fr-f820-00046_instruction-manual_1811886617.webp)
Parameters
(A) Application parameters
FR-F800
5 - 445
Selection of trace mode (Pr. 1021)
●
Select how to save the trace data which results from sampling the inverter status.
●
There are two trace data save methods, memory mode and recorder mode.
Setting of sampling cycle (interval) and number of sampling channels (Pr. 1022, Pr. 1023)
●
Set the sampling cycle (interval).
The shortest cycle in the recorder mode is 1 ms. When the recorder mode is set, sampling is
performed at a sampling cycle of 1 ms even if "0, 1" is set to Pr. 1022 "Sampling cycle".
●
When the memory mode is set, the number of analog channels to sample can be set in the Pr.
1023 "Number of analog channels". Start setting from the smaller channel number. Up to eight
channels can be set. The sampling time becomes shorter the more channels are set.
The number of channels is always 8 when the recorder mode is used or when digital channels are
used.
●
The sampling time differs according to the sampling cycle and number of sampling channels.
Pr. 1021
setting
Mode
Description
0
Memory
mode
In this mode, trace data is saved sequentially to internal RAM on the inverter.
If automatic transfer is set, the trace data in internal RAM is transferred to USB memory device
when the trigger is being generated.
Data can be transferred to a USB memory device as long as data is held in internal RAM.
Trace data in internal RAM is cleared when the power supply is turned OFF or when the inverter
is reset.
1
Memory
mode
(automatic
transfer)
2
Recorder
mode
In this mode, trace data is saved directly to USB memory device.
Sampling data is fixed at eight analog channels and eight digital channels.
The sampling cycle in this mode is longer than in the memory mode. (1 ms or longer)
Tab. 5-213:
Selection of trace mode
NOTES
When the trace function is used in the recorder mode, use a USB memory device having at least
1 GB of free space.
Data transferred to USB is saved in the "TRC" folder under the "FR_INV" folder.
Up to 99 sets of trace data can be saved in the USB memory device. When data transfer to USB
memory device reaches 99 sets of trace data, data is successively overwritten starting with the
older data.
Number of channels
Memory mode sampling time
Minimum (Pr. 1022 = "0")
Maximum (Pr. 1022 = "9")
1
213 ms
1704 s
2
160 ms
1280 s
3
128 ms
1024 s
4
106.5 ms
852 s
5
91.8 ms
728 s
6
80.0 ms
640 s
7
71.8 ms
568 s
8
60 ms
512 s
Tab. 5-214:
Memory mode sampling time
Содержание FR-F820-00046
Страница 2: ......
Страница 4: ......
Страница 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Страница 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Страница 874: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 900: ...Outline dimension drawings Specifications 8 26 ...
Страница 928: ...EC Declarations of Conformity Appendix A 28 A 6 EC Declarations of Conformity A 6 1 FR F820 FR F840 FR F842 series ...
Страница 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Страница 930: ...EC Declarations of Conformity Appendix A 30 ...
Страница 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Страница 932: ...EC Declarations of Conformity Appendix A 32 ...
Страница 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Страница 934: ...EC Declarations of Conformity Appendix A 34 ...
Страница 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Страница 936: ...EC Declarations of Conformity Appendix A 36 ...
Страница 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Страница 938: ...EC Declarations of Conformity Appendix A 38 ...
Страница 939: ......