FR-F800
5 - 43
Parameters
Control method
Valid/invalid status of monitor outputs during the test run
: Valid
×:
Invalid (always displays 0)
Δ:
Displays accumulated value before the test
⎯
: Not
monitored
Different output interface (operation panel, parameter unit, terminal FM/CA or terminal AM) can
output different monitored items. For details, refer to page 5-211.
When the operation is switched to the test run, "0" is displayed. When PM motor control is selected
again after a test run, the output current peak value and the electronic thermal relay load factor
from the last operation are displayed.
The monitored status can be output via the terminal AM only.
When the operation is switched to the test run, accumulated thermal value is reduced by consid-
ering the output current is "0".
Types of monitor
DU/PU
Monitor
display
FM/AM/
CA
Output
Types of monitor
DU/PU
Monitor
display
FM/AM/
CA
Output
Output frequency
PID deviation
Fault display
⎯
Input terminal status
⎯
Frequency setting value
Output terminal status
⎯
Running speed
Option input terminal status
⎯
Converter output voltage
Option output terminal status
⎯
Electric thermal relay load
factor
Motor thermal load factor
Output current peak value
Inverter thermal load factor
Converter output voltage peak
value
PTC thermistor value
⎯
Load meter
PID measured value 2
Cumulative energization time
⎯
PID input pressure value
Reference voltage output
⎯
Remote output 1
Actual operation time
⎯
Remote output 2
Cumulative power
Δ
⎯
Remote output 3
Trace status
×
Remote output 4
Station number
(RS-485 terminals)
⎯
PID manipulated amount
Station number (PU connector)
⎯
Second PID set point
Station number (CC-Link)
⎯
Second PID measured value
Energy saving effect
Second PID deviation
Cumulative energy saving
Δ
⎯
Second PID measured value 2
PID set point
Second PID manipulated amount
PID measured value
Tab. 5-16:
Monitor outputs during the test run
Parameters referred to
Pr. 52
Operation panel main monitor selection
=>
Pr. 158
AM terminal function selection
=>
Содержание FR-F820-00046
Страница 2: ......
Страница 4: ......
Страница 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Страница 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Страница 874: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 900: ...Outline dimension drawings Specifications 8 26 ...
Страница 928: ...EC Declarations of Conformity Appendix A 28 A 6 EC Declarations of Conformity A 6 1 FR F820 FR F840 FR F842 series ...
Страница 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Страница 930: ...EC Declarations of Conformity Appendix A 30 ...
Страница 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Страница 932: ...EC Declarations of Conformity Appendix A 32 ...
Страница 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Страница 934: ...EC Declarations of Conformity Appendix A 34 ...
Страница 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Страница 936: ...EC Declarations of Conformity Appendix A 36 ...
Страница 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Страница 938: ...EC Declarations of Conformity Appendix A 38 ...
Страница 939: ......