3-4
4. Physiological
alarm
area
Displays physiological alarm messages.
5. Apnea alarm off icon area
Displays apnea alarm off icon
when apnea alarm is switched off in
non-mechanical ventilation mode.
6. Alarm silence icon area
Displays alarm silence icon and 120 s countdown time.
7. System time area
Displays system time of the anesthesia machine.
8. Technical
alarm
area
Displays technical alarm messages. When multiple alarms occur, they are displayed
cyclically.
9. Power supply state icon area
Displays power source or battery icon.The icon
is displayed when the anesthesia
machine is powered by AC power source. The battery icon is displayed when the
anesthesia machine is battery powered to indicate battery capacity. For details, refer
to
2.3 Batteries
.
10. [
Vent Mode
] shortcut key
Used to select mechanical ventilation mode.
11. [
Alarm
Setup
] shortcut key
Used to change the alarm settings for the anesthetic ventilator, gas modules or BIS
module.
12. [
Screens
] shortcut key
Used to set user screen.
13. [
User Setup
] shortcut key
Used to change the settings for TV compensation, O2 monitoring source, gas module,
BIS module, screen, sound etc.
14. [
Maintenance
] shortcut key
Used to perform leak test, calibrate O2 sensor and flow sensor, view trend graph, trend
table and alarm logbook, and set language, system time, pressure unit, IP address etc.
15. Timer setup shortcut key
Used to start, stop and reset the timer.
16. Parameter setup shortcut keys area
Used to set the parameters related to the selected mechanical ventilation mode. The
arrangement of the shortcut keys in this area varies depending on the selected
mechanical ventilation mode. For details, refer to
4 Operations and Ventilation Setup
.
17 System prompt message area
Содержание WATO EX-65
Страница 1: ...WATO EX 65 Anesthesia Machine Operator s Manual ...
Страница 2: ......
Страница 8: ...VI FOR YOUR NOTES ...
Страница 16: ...8 FOR YOUR NOTES ...
Страница 25: ...2 3 2 2 Equipment Appearance 2 2 1 Front View Display and control panel ...
Страница 27: ...2 5 Breathing system ...
Страница 29: ...2 7 2 2 2 Rear View Power supply ...
Страница 31: ...2 9 Anesthesia information system CIS ...
Страница 42: ...3 8 FOR YOUR NOTES ...
Страница 66: ...4 24 FOR YOUR NOTES ...
Страница 108: ...7 10 7 8 AGSS Transfer Tube Maintenance Check the tube of the AGSS transfer system Replace it if it is damaged ...
Страница 148: ...11 8 FOR YOUR NOTES ...
Страница 152: ...12 4 FOR YOUR NOTES ...
Страница 154: ...13 2 13 1 1 Breathing System Diagrams 14 15 16 17 18 19 20 21 22 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 168: ...13 16 5 Turn the rotary handle clockwise for 90 degrees 6 Let the rotary handle fall to lock the sodalime canister ...
Страница 222: ...A 6 FOR YOUR NOTES ...
Страница 244: ...B 22 FOR YOUR NOTES ...
Страница 250: ...C 6 FOR YOUR NOTES ...
Страница 264: ...D 14 FOR YOUR NOTES ...
Страница 274: ......
Страница 275: ......
Страница 276: ...P N 046 000203 00 1 0 ...