B-1
B
Product Specifications
The anesthesia machine is integrated with pressure restriction device, expiratory volume
monitor, breathing system with alarm system, pressure measurement device, anesthetic
ventilation system, AGSS transfer and receiving system, anesthetic gas delivery device,
anesthetic ventilator, O2 monitor, CO2 monitor and AG monitor, where:
The pressure restriction device, expiratory volume monitor and breathing system with
alarm system comply with GB 9706.29 and IEC 60601-2-13.
The pressure measurement device and anesthetic ventilation system comply with ISO
8835-2.
The AGSS transfer and receiving system complies with ISO 8835-3.
The anesthetic gas delivery device complies with ISO 8835-4.
The anesthetic ventilator complies with ISO 8835-5.
The O2 monitor complies with ISO 7767-1997 and ISO 21647-2004.
The CO2 monitor complies with ISO 9918-1993 and ISO 21647-2004.
The AG monitor complies with ISO 11196-1996 and ISO 21647-2004.
B.1 Safety Specifications
Type of protection against
electric shock
Class I equipment with internal electrical power supply.
Where the integrity of the external protective earth (ground) in
the installation or its conductors is in doubt, the equipment shall
be operated from its internal electrical power supply (batteries).
Degree of protection against
electric shock
BF, defibrillation-proof
Operating mode
Continuous
Degree of protection against
hazards of explosion
Ordinary equipment, without protection against explosion; not
for use with flammable anesthetics.
Degree of protection against
harmful ingress of water
Ordinary equipment, without protection against ingress of
water--IPX0 (IEC 529)
Electrical connections between
the equipment and the patient
Non-electrical connections
Equipment type
Mobile
Disinfection
Steam autoclavable or disinfectable
Содержание WATO EX-65
Страница 1: ...WATO EX 65 Anesthesia Machine Operator s Manual ...
Страница 2: ......
Страница 8: ...VI FOR YOUR NOTES ...
Страница 16: ...8 FOR YOUR NOTES ...
Страница 25: ...2 3 2 2 Equipment Appearance 2 2 1 Front View Display and control panel ...
Страница 27: ...2 5 Breathing system ...
Страница 29: ...2 7 2 2 2 Rear View Power supply ...
Страница 31: ...2 9 Anesthesia information system CIS ...
Страница 42: ...3 8 FOR YOUR NOTES ...
Страница 66: ...4 24 FOR YOUR NOTES ...
Страница 108: ...7 10 7 8 AGSS Transfer Tube Maintenance Check the tube of the AGSS transfer system Replace it if it is damaged ...
Страница 148: ...11 8 FOR YOUR NOTES ...
Страница 152: ...12 4 FOR YOUR NOTES ...
Страница 154: ...13 2 13 1 1 Breathing System Diagrams 14 15 16 17 18 19 20 21 22 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 168: ...13 16 5 Turn the rotary handle clockwise for 90 degrees 6 Let the rotary handle fall to lock the sodalime canister ...
Страница 222: ...A 6 FOR YOUR NOTES ...
Страница 244: ...B 22 FOR YOUR NOTES ...
Страница 250: ...C 6 FOR YOUR NOTES ...
Страница 264: ...D 14 FOR YOUR NOTES ...
Страница 274: ......
Страница 275: ......
Страница 276: ...P N 046 000203 00 1 0 ...