SmartTime Static Timing Analyzer User Guide
44
Understanding Timing Violation Reports
The timing violation report contains the following sections:
Header
The header lists:
•
The report type
•
The version of Designer used to generate the report
•
The date and time the report was generated
•
General design information (name, family, etc.)
Paths
The paths section lists the timing information for the violated paths in the design.
The number of paths displayed is controlled by two parameters:
•
A maximum slack threshold to report
•
A maximum number or path to report
By default, the slack threshold is 0 and the number of paths is limited. The default maximum number of
paths reported is 100.
All clocks domains are mixed in this report. The paths are listed by decreasing slack.
You can also choose to expand one or more paths. By default, no paths are expanded. For details, see the
timing violation report options.
Содержание SmartTime
Страница 2: ......
Страница 6: ......
Страница 15: ...SmartTime Static Timing Analyzer User Guide 15 SmartTime Timing Analyzer ...
Страница 31: ...SmartTime Static Timing Analyzer User Guide 31 Advanced Timing Analysis ...
Страница 37: ...SmartTime Static Timing Analyzer User Guide 37 Generating Timing Reports ...
Страница 57: ...SmartTime Static Timing Analyzer User Guide 57 Timing Concepts ...
Страница 66: ...SmartTime Static Timing Analyzer User Guide 66 ...
Страница 91: ...SmartTime Static Timing Analyzer User Guide 91 Q_reg NOT2 end not u1 NOT1 MUX2 not u2 NOT2 NOT1 endmodule ...
Страница 92: ...SmartTime Static Timing Analyzer User Guide 92 Dialog Boxes ...
Страница 118: ...SmartTime Static Timing Analyzer User Guide 118 Tcl Commands ...