SmartTime Static Timing Analyzer User Guide
127
Value
Description
text
Generates a text report (default).
csv
Generates the report in a comma-separated value format which you can import
into a spreadsheet.
-filename
Specifies the file name for the generated report.
Timing Options and Values
Parameter/Value
Description
-max_parallel_paths
<number>
Specifies the max number of parallel paths. Parallel paths
are timing paths with the same start and end points.
-max_paths <number>
Specifies the max number of paths to display for each set.
This value is a positive integer value greater than zero.
Default is 100.
-print_summary <yes|no>
Yes to include and No to exclude the summary section in
the timing report.
-use_slack_threshold
<yes|no>
Yes to include slack threshold and no to exclude threshold
in the timing report. The default is to exclude slack
threshold.
-slack_threshold <double> Specifies the threshold value to consider when reporting
path slacks. This value is in nanoseconds (ns). By default,
there is no threshold (all slacks reported).
-print_paths (yes|no)
Specifies whether the path section (clock domains and in-
to-out paths) will be printed in the timing report. Yes to
include path sections (default) and no to exclude path
sections from the timing report.
-max_expanded_paths
<number>
Specifies the max number of paths to expand per set. This
value is a positive integer value greater than zero. Default
is 100.
-include_user_sets
(yes|no)
If yes, the user set is included in the timing report. If no, the
user set is excluded in the timing report.
-include_clock_domains
(yes|no)
Yes to include and no to exclude clock domains in the
timing report.
-select_clock_domains
<clock_name_list>
Defines the clock domain to be considered in the clock
domain section. The domain list is a series of strings with
domain names separated by spaces. Both the summary
and the path sections in the timing report display only the
listed clock domains in the clock_name_list.
-limit_max_paths (yes|no) Yes to limit the number of paths to report. No to specify that
there is no limit to the number of paths to report (the
default).
Содержание SmartTime
Страница 2: ......
Страница 6: ......
Страница 15: ...SmartTime Static Timing Analyzer User Guide 15 SmartTime Timing Analyzer ...
Страница 31: ...SmartTime Static Timing Analyzer User Guide 31 Advanced Timing Analysis ...
Страница 37: ...SmartTime Static Timing Analyzer User Guide 37 Generating Timing Reports ...
Страница 57: ...SmartTime Static Timing Analyzer User Guide 57 Timing Concepts ...
Страница 66: ...SmartTime Static Timing Analyzer User Guide 66 ...
Страница 91: ...SmartTime Static Timing Analyzer User Guide 91 Q_reg NOT2 end not u1 NOT1 MUX2 not u2 NOT2 NOT1 endmodule ...
Страница 92: ...SmartTime Static Timing Analyzer User Guide 92 Dialog Boxes ...
Страница 118: ...SmartTime Static Timing Analyzer User Guide 118 Tcl Commands ...