SmartTime Static Timing Analyzer User Guide
53
Understanding Datasheet Reports
The datasheet report displays the external characteristics of the design. . You can generate this report from
SmartTime Max/Min Delay Analysis View. It contains three tables:
•
Pin Description
•
DC Electrical Characteristics
•
AC Electrical Characteristics
Figure 27 · Datasheet Report
Pin Description
Provides the port name in the netlist, location on the package, type of port, and I/O technology assigned to
it. Types can be input, output, inout, or clock. Clock ports are ports shown as "clock" in the Clock domain
browser.
DC Electrical Characteristics
Provides the parameters of the different I/O technologies used in the design. The number of parameters
displayed depends on the family for which you have created the design.