SmartTime Static Timing Analyzer User Guide
77
Figure 51 · SmartTime Register to Register Delay
4. Double-click a path row to open the Expanded Path window. The window shows a calculation of the
data arrival and required times along with a schematic of the path (as shown in the figure below).
Note:
The Timing Numbers in these reports may vary slightly with different versions of the Libero Software,
and may not be exactly the same as what you will see when you run the tutorial.
Figure 52 · Register-to-Register Expanded Path View
5. Select
External Setup
to display the Input to Register timing. Select
Path 3
. The Input Arrival time
from the EN pin to Q_int[27]:EN is 4.547 ns (as shown in the figure below).