SmartTime Static Timing Analyzer User Guide
47
Understanding Constraints Coverage Reports
The constraint coverage displays the overall coverage of the timing constraints set on the current design.
You can generate this report either from within Designer or within SmartTime Analyzer. The report contains
three sections:
•
Coverage Summary
•
Results by Clock Domain
•
Enhancement Suggestions
Figure 25 · Constraints Coverage Report
Coverage Summary
The coverage summary gives statistical information on the timing constraint in the design. For each type of
timing checks (Setup, Recovery, Output, Hold and Removal), it specifies how many are Met (there is a