Section 5 - Maintenance
90-899883234 JANUARY 2008
Page 109
7. Snap the quick‑connect fitting with the water hose into the flush socket on the engine.
a
b
c
18489
a -
Water hose
b -
Quick‑connect fitting (water hose
end)
c -
Flush socket
8. Open the water source of the water hose to a full flow.
9. Allow the water to flush the sterndrive for 30 seconds.
10. Place the remote control in neutral idle speed position and start engine.
NOTICE
Without sufficient cooling water, the engine, the water pump, and other components will
overheat and suffer damage. Provide a sufficient supply of water to the water inlets during
operation.
11. Operate the engine at idle speed in neutral gear. Do not exceed 1200 RPM.
12. Monitor the engine temperature while operating the engine.
13. Flush the engine for 5 to 10 minutes or until discharge water is clear.
14. Shut off the engine.
15. Allow the water to flush the sterndrive for 10 seconds.
16. Turn off the water source.
Содержание Axius 350 MAG
Страница 26: ...Section 1 Warranty Notes Page 18 90 899883234 JANUARY 2008 ...
Страница 42: ...Section 2 Getting to Know Your Power Package Notes Page 34 90 899883234 JANUARY 2008 ...
Страница 76: ...Section 4 Specifications Notes Page 68 90 899883234 JANUARY 2008 ...
Страница 120: ...Section 5 Maintenance Notes Page 112 90 899883234 JANUARY 2008 ...
Страница 138: ...Section 6 Storage Notes Page 130 90 899883234 JANUARY 2008 ...