IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 166
L08.09
Ground Fault
01***
00, 01
-
00: Disable
01: Enable
L08.10
Fan Operation Selection
00
00, 01
-
00: Fan On - Run with Time (L08.11)
01: Fan Always On
L08.11
Fan Off-Delay Time
60
0–300
sec
L08.12
Ambient Temp
40
-10–50
°C
L08.15
OL2 Sel @ Low Speed
01
00, 01
-
00: Disabled
01: Enabled
L08.18
Soft CLA Sel
01
00, 01
-
00: Disabled
01: Enabled
L08.19
Overheat Pre-Alarm Frequency
Reduction Rate
0.8
0.1, 0.9
%
L08.35
Mounting Selection
00
00–03
-
00: Disabled (standard installation)
01: Side-By-Side
02: NEMA 1 Standard
03: Finless
L08.41
High Current Alarm Selection
00
00, 01
-
00: Disable
01: Enable
L09.01
Auto Reset Select
01
00, 01
-
00: Disable
01: Enable
L09.02
Auto Reset Attempts
03
00–10
-
L09.03
Auto Reset Time
0.5
0.5–180.0
sec
L09.04
Auto Reset Fault Select 1
0001
0000–FFFF
-
L09.05
Auto Reset Fault Select 2
E000
0000–FFFF
-
L09.06
Output Contact (MC-MB-MA) Select
01
00, 01
-
00: Disabled (No Fault Relay)
01: Enabled (Fault Relay Active)
N02.01
AFR Tuning
1.00
0.00–10.00
-
N02.02
AFR Detection Time
50
0–2000
ms
N02.03
AFR Time Constant
750
0–2000
ms
N02.04
AFR Limit
5.0
0.0–60.0
Hz
-
N02.05
OLV Stabilization Level
00
00–11, FF
-
Parameter
Parameter Name
Default
Range
Units
Page
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...