IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 99
1C Swift Lift Active
Closed when Swift Lift is active
1D BaseBlk N.C.
Open during baseblock 2
-
20 Auto-Rst Attempt
Closed when auto reset is enabled
21 Overload OL1
Closed when an OL1 Overload fault code occurs
22 Overheat Prealarm
Closed when “OH” is displayed on keypad
23 Torque Limit
Closed when current Torque Limit is reached
26 Run Cmd is input
Closed when either a Fwd or Rev Run Command
is active
-
27 Load Check Det
Closed when Load Check detected
29 Upper Limit
Closed when Upper Limit-SLOW DOWN or
Upper Limit STOP is input
2A During Run1
Closed when the VFD is Outputting Voltage
-
2B During Fast Stop
Closed During Fast Stop
2F Load Weakening
Closed during Load Weakening
30 Lower Limit
Closed when Lower Limit-SLOW DOWN or
Lower Limit STOP is input
31 Upper/Lower Limit
Closed when Upper Limit-SLOW DOWN or
Upper Limit STOP or Lower Limit-SLOW DOWN
or Lower Limit STOP is input
37 Maintenance
Closed when the timer reaches C12.05
39 Drive Enable
Closed when drive enable is active
-
3A Overheat Pre Alarm
Time Limit
Closed when OH Pre Alarm Time Limit is
reached
3D During Speed Search Closed during Speed Search
-
3F Klixon
Closed when MFDI 56 or 57 is on - motor is
overheating
40~FF Fault Annunciate Closed on specific faults
-
101 Inverse Zero Speed Open when the output frequency is below
D01.01
102 Inverse Frequency
Agree 1
Open when Frequency Reference and
Frequency Output agree
-
103 Inverse Frequency
Set 1
Open when Output Frequency Reference equals
L04.01
104 Inverse Freq
Detect 1
Open when output frequency is < L04.01.
105 Inverse Freq
Detect 2
Open when output frequency is > L04.01.
106 Inverse Inverter
Ready
Open when VFD is not in a fault state
-
107 Inverse DC Bus
Undervolt
Open when DC Bus voltage drops below UV trip
point
-
108 Inverse Baseblock
N.O.
Open when VFD is not outputting voltage
-
109 Inverse Frequency
Reference Source
Open when the frequency reference is input from
the keypad (O02.01)
Parameter Name
Function
Page
Range
Default
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...