IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 159
127: (Inverse) Load Check Detect
129: (Inverse) Upper Limit
12A: (Inverse) During Run 1
12B: (Inverse) During Fast Stop
12F: (Inverse) Load Weakening
130: (Inverse) Lower Limit
131: (Inverse) Upper/Lower Limit
135: (Inverse) Load Check Fault
Detection
137: (Inverse) Maintenance
139: (Inverse) Drive Enable
13A: (Inverse) Overheat Pre-Alarm
Time Limit
13D: (Inverse) During Speed Search
13F: (Inverse) Klixon
140~1FF: (Inverse) Fault Annunciate
H02.02
Output Terminal P1 Select
(See H02.01 for selections)
00F*
000–1FF
-
H02.03
Output Terminal P2 Select
(See H02.01 for selections)
00F*
000–1FF
-
H03.01
Terminal A1 Signal Select
00*
00
-
00: 0 to 10 VDC
H03.02
Terminal A1 Select
00
00–1F
-
00: Frequency Bias
01: Frequency Gain
02: Aux Speed Reference 1
03: Aux Speed Reference 2
04: Output Voltage Bias
07: OT/UT Detection Level
0F: Not Used
10: Forward Torque Limit
11: Reverse Torque Limit
12: Regen Torque Limit
15: FWD/REV Torque Limit
1F: Not Used
H03.03
Terminal A1 Gain
100.0
-999.9–999.9
%
H03.04
Terminal A1 Bias
0.0
-999.9–999.9
%
H03.09
Terminal A2 Signal Select
02
00, 02, 03
-
00: 0 to 10 VDC
02: 4 to 20 mA
03: 0 to 20 mA
Parameter
Parameter Name
Default
Range
Units
Page
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...