![background image](http://html1.mh-extra.com/html/magnetek/impulse-g-mini/impulse-g-mini_technical-manual_3605595059.webp)
IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 59
5.1.3.6
Fast Stop (H01.xx = 40 or 42)
Figure 5-12: H01.XX = 40 or 42 (Fast Stop) without DC Injection
Figure 5-13: H01.XX = 40 or 42 (Fast Stop) with DC Injection
5.1.3.7
Motor Rotation Change
This parameter allows you to change the motor direction without changing the motor leads.
Parameter
Name
Function
Range
Default
B03.04
Change Rotation
Reverse motor direction
00–01
00
00 Normal Rotation
01 Exchange Phases