IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 62
NOTE:
Assume B03.03 is set to “00” (Decel to Stop).
Figure 5-14: Normal Accel/Decel Time and Multiple Accel/Decel Changeover
5.1.5 Jump Frequencies
This function allows the “jumping” of frequencies so that the motor can operate without resonant vibrations caused
by some machine systems. This function is also used for deadband control. Setting the jump frequency to 0.0 Hz
disables this function.
Parameter
Name
Function
Range
Default
B08.01
Jump Frequency 1
First of three jump frequencies.
0.0–150.0 Hz
0.0
B08.02
Jump Frequency 2
Second of three jump frequencies.
0.0–150.0 Hz
0.0
B08.03
Jump Frequency 3
Third of three jump frequencies.
0.0–150.0 Hz
0.0
B08.04
Jump Bandwidth
Jump frequency reference bandwidth.
0.0–20.0 Hz
1.0
Run Command
H01.xx = 1A
Accel / Decel
Changeover
Frequency Output
Brake Output
B05.04
B05.02
B05.03
B05.01
B05.01
B05.02