5.2.14 Inching Control
Inching Control function can be enabled by programming a digital input to H01.xx = 17, 18, or 19. The frequency
reference used during inching is determined by B01.17 (Jog Reference).
Figure 5-21: Inching Function and Inching Repeat
NOTE:
C13.01 did not expire during the second inch forward command.
Parameter
Name
Function
Range
Default
C13.01
Inch Run Time
Inching Control run time.
0.00–2.55 sec
1.00
C13.02
Repeat Delay Time
Inching Control repeat delay time.
0.00–2.55 sec
1.00
H01.01 ~
H01.07
Terminal Selection
Multi-Function Input Terminals
00–81
-
17 Forward Inch
18 Reverse Inch
19 Inch Repeat
CAUTION
A directional input is not needed on terminals S1 or S2 to run the motor.