5.3.4 Dwell
The Dwell function is used to temporarily hold the output frequency at a set reference for a set time. This function
can be used when driving a motor with a heavy starting load. This pause in acceleration reduces traditionally high
starting current. Enable by setting H01.01–H01.07 = 65.
NOTE:
This function is only available when using Braketronic (A01.03 = 06).
Figure 5-24: Dwell Function
Parameter
Name
Function
Range
Default
D08.01
Dwell Reference @ Start
Sets Dwell frequency reference at start.
0.0–150.0 Hz
0.0
D08.02
Dwell Time @ Start
Sets the time duration for the Dwell function at
start.
0.0–10.0 sec
0.0
D08.03
Dwell Reference @ Stop
Sets Dwell frequency reference at stop.
0.0–150.0 Hz
0.0
D08.04
Dwell Time @ Stop
Sets the time duration for the Dwell function at
stop.
0.0–10.0 sec
0.0