IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 146
B03.15
Reference Selection
01
00–04
-
00: Keypad
01: Terminals
02: Modbus Communication
03: Option PCB
04: Pulse Input
B03.16
Reference Source
01
00–03
-
00: Keypad
01: Terminals
02: Modbus Communication
03: Option PCB
B05.01
Accel Time 1
5.0*
0.0–25.5
sec
B05.02
Decel Time 1
3.0*
0.0–25.5
sec
B05.03
Accel Time 2
2.0
0.0–6000.0
sec
B05.04
Decel Time 2
2.0
0.0–6000.0
sec
B05.05
Accel Time N Change
2.0
0.0–25.5
sec
B05.06
Decel Time N Change
2.0
0.0–25.5
sec
B05.08
Fast Stop Time
1.0
0.0–25.5
sec
B05.09
Accel/Decel Units
01
00–01
-
00: Unit of 0.01 Seconds
01: Unit of 0.1 Seconds
B05.10
Accel/Decel Switch Frequency
120.0
0.0–150.0
Hz
B05.11
Switch Frequency Compare
01
00–01
-
00: Lower Switch Frequency
01: Upper Switch Frequency
B05.12
Accel Time 3
3.0
0.0–6000.0
sec
B05.13
Decel Time 3
3.0
0.0–6000.0
sec
B05.14
Accel Time 4
3.0
0.0–6000.0
sec
B05.15
Decel Time 4
3.0
0.0–6000.0
sec
B08.01
Jump Frequency 1
0.0
0.0–150.0
Hz
B08.02
Jump Frequency 2
0.0
0.0–150.0
Hz
B08.03
Jump Frequency 3
0.0
0.0–150.0
Hz
B08.04
Jump Frequency Width
1.0
0.0–20.0
Hz
C01.01
Quick Stop
00*
00, 01
-
00: Disabled
01: Enabled
C01.02
Quick Stop Time
1.0
0.0–25.5
sec
C01.03
Reverse Plug
00
00, 01
-
00: Disabled
01: Enabled
Parameter
Parameter Name
Default
Range
Units
Page
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...