IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 65
5.2.2 Reverse Plug Simulation™
The
Reverse Plug Simulation
function provides an alternate deceleration time/acceleration time at a change
direction command. The deceleration time and the acceleration time are set independently of the normal
acceleration and deceleration times.
Figure 5-16: Reverse Plug Simulation
Parameter
Display
Function
Range
Default
C01.03
Reverse Plug
Determines whether Reverse Plug Simulation
is enabled.
00–01
00
00 Disabled
01 Enabled
C01.04
Reverse Plug Decel Time
Deceleration time during Reverse Plug
Simulation.
0.0–25.5 sec
2.0
C01.05
Reverse Plug Accel Time
Acceleration time during Reverse Plug
Simulation
0.0–25.5 sec
2.0