IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 64
5.2.1 Quick Stop
The
Quick Stop
function provides an alternate deceleration time when the run command is removed.
NOTE:
The Quick Stop Deceleration time differs from the normal deceleration time and is applied only when the
RUN command is removed.
* Initial value is determined by X-Press Programming (
Figure 5-15: Quick Stop
Parameter
Name
Function
Range
Default
C01.01
Quick Stop
Determines whether Quick Stop is enabled
00–01
00*
00 Disabled
01 Enabled
C01.02
Quick Stop Time
Deceleration time during Quick Stop function.
0.0–25.5 sec
1.0